3.1.4 Pole Mounting Procedures
The following figure illustrates the two pole mounting options:
back-to-back (left) and two systems (right).
figure 3-5 Pole mounted systems
•
Before starting the mounting procedure, check the pole diameter of the pole to
which the units will be installed; then, cut the thread-bolts (see
table 3-3
Components of pole mounting kits
, pos. 5) to the required length according to the
following table, which also states the appropriate cable bridge lengths:
Pole-diameter
(mm)
100 110 120
130
140
150
160
170
180 190 200
Length of Thread-
Bolt (mm)
216 226 236
246
256
266
276
286
296 306 317
Length of cable
bridge (mm)
(back-to-back)
800 2000
Length of cable
bridge (mm)
(for 2 systems)
800 2000
table 3-2 Required length of thread-bolts and cable bridge