EMX 156 Installation Guide 2

3.If you are connecting more than one EMX 156 module 

to your Infinet controller, connect the second one to the 
bottom of the first.

4.Set the BOARD switch (upper right) to 1 on the first EMX 

156, and the BOARD switch to 2 on the second EMX 156.  
If you do not plan to connect more than one EMX 156 
module, set the BOARD switch to 1.

Never set two modules of the same model number to the 
same board number.

3. Connect the External Power Supply 
(if necessary)

If you are installing multiple modules, you may need an 
external power supply. To determine what you need, refer 
to the ACC EMX Modules Configuration Guide.

Figure 2 shows where you connect the external power supply 
to the 2-pin Berg type connector on the EMX 156.

Figure 2.  Location of External Power Connection 
and External Power Supply Jumper

4. Reposition Jumper of One Module

The Berg type connector immediately to the left of the ex-
ternal power supply connection has a jumper that you 
reposition to indicate you are using external power.

Figure 3 shows the jumper in the two possible positions, one 
for the internal power supply, the other for the external. Move 
the jumper to the external power supply position.

Connect
External
Power 
Supply
Here

Move

External

Power 

Jumper

EMX156

BOARD

OUTPUT

A

OVERRIDE

A

B

OUTPUT

B

LOAD

A

LOAD

B

DATE

1

2

U

L

INPUTS

VOLTS 24V

AMPS

36MA

OUTPUTS

VOLTS 240V

AMPS 3.5A

LISTED

ACCESSORY EQUIPMENT

58B2

FOR USE WITH

SCX

LCX AND TCX UNITS

,

24VDC
CLASS

I I

AUTO OFF ON AUTO OFF ON

R

Override

Switches

You change the jumper position only on the module or mod-
ules connected to the external power supply, not on any other 
modules.

Note

You need to change the jumper position only on the mod-
ule(s) actually connected to an external power supply. Never 
change the jumper position of other modules.

Figure 3.  Jumper Positions for Internal and External 
Power Supplies

Each is set to the internal position when you receive it.

Wire the Outputs

You wire the outputs as follows:

1.Slip the appropriate wires under the Load A screws and 

tighten the screw down on it.

2.Slip the appropriate wires under the Load B screws and 

tighten the screws down on it.

Figure 4 illustrates the wiring for Form A outputs.

Figure 4.  Wiring Diagram for Form A Outputs 

Troubleshoot

If you have problems with the Infinet controller after in-
stalling the module, see your Andover Controls 
representative for details.

Refer to the EnergyNet and Infinet Configuration Guide 
for information on how to troubleshoot network and pow-
er supply problems.

Jumper Position,
External Power
Supply

Jumper Position,
Internal Power
Supply

Load A