General Rules 

ADSM302  is  a  multifunctional  digital  microscope  individually  designed,  developed  and  manufactured  by 
Shenzhen Andonstar Technology Co., Ltd. It realized Full HD, high object distance, multifunction, multi-output 
at  the  same  time.  With  help  of  the  Andonstar  measuring  software,  it  can  easily  meet  many  different 
requirements in many industries, such as industrial overhaul and teaching demonstration. And it’s appearance 
design  combines  more  ergonomic  consideration,  provides  users  better  experience.  We  sincerely  wish  this 
product can release your eyes and improve your work quality. Thanks for your support.   

 

 

This operation manual allows you to work safely with the digital Microscope. Please keep this manual for 
your information. Liability is void for any damage caused by not follow this manual.   

 

Failure to follow the warnings and instructions may cause electric shock, fire and/or serious injury. 

 

Not following this note can cause permanent damage to the device. 

 

Storage and transport: Improper transport can harm the device; Always transport this device in the provided 
box in order to prevent damage. 

 

Information on disposal: Electronic equipment does not belong to domestic waste, but must be disposed in 
accordance with the applicable statutory provisions. 

 

In order to bring customers a better experience, we may change the product a little bit during perfecting it. 
The description in this instruction is for reference ONLY. Thanks for understanding. 

 

Safety 

1.Keep the tool dry, clean, free from oil, water, gas or other materials capable of causing corrosion. 

2.This appliance is not intended for use by people with limited physical, sensory or mental capabilities. 

3.Keep bystanders, children away while operating the tool. 

4.Do not overreach, keep proper footing and balance at all time. 

 

 

Содержание ADSM302

Страница 1: ...Andonstar ADSM302 Digital Microscope Andonstar ADSM302 Digital Microscope USER MANUAL...

Страница 2: ...Andonstar ADSM302 Digital Microscope V1 1 2018 05 10...

Страница 3: ...6 General Use 7 Use Individually 7 Select operating mode 7 System settings 7 Capture mode 7 Record mode 7 HDMI 8 HDMI FAQ 8 USB 8 Software Installation 8 Software Overview 10 Icon Definitions 10 Inte...

Страница 4: ...ed by not follow this manual Failure to follow the warnings and instructions may cause electric shock fire and or serious injury Not following this note can cause permanent damage to the device Storag...

Страница 5: ...tion 12M Photo format JPEG Focus range 5cm to 22cm Frame rate Max 30f s under 600 Lus Brightness Video output interface HDMI AV Storage Micro SD card up to 32G option PC support Yes for Windows XP 7 8...

Страница 6: ...Digital Microscope 4 Parts of ADSM302 Main Device Fasten screw It aim to adjust the compactness between the Lifting stand and the Distance controllers so users can fasten the distance from the lens to...

Страница 7: ...rom 2 0 to 2 0 Lock unlock to lock the file when it s recording So the video file which has been locked won t be covered by new files when the memory card is full Sharpness up down there are three lev...

Страница 8: ...ssible outputs its own monitor HDMI AV TV USB and memory card AV output Memory card USB output HDMI output Connect the device to the switch Connect the switch to the power supply Connect the two goose...

Страница 9: ...n in different modes standby mode capture mode record mode image playback mode video playback mode If the files are videos press OK to play the video file Lock the file which is being recording System...

Страница 10: ...ure the device is switched on Why the image is not clear Please adjust the object distance and the focus controller check the direction of the LED lights and make sure the lens is clean enough Remote...

Страница 11: ...Andonstar ADSM302 Digital Microscope 9...

Страница 12: ...of any 2 points Add text Measuring a rectangular width height circumference area Distance of 2 lines Length Measuring an ellipse Long axis radius short axis radius circumference area 3 points circle...

Страница 13: ...s definitions Users can choose to hide or show this toolbar in View Toolbars and Docking Windows Standard Picture Browser Here is where users can review all pictures they ve captured Users can also ed...

Страница 14: ...d image analysis Calibration Management and Measuring Results These two windows shows at the same place users can switch at the bottom of this window Calibration Management Shows the list of different...

Страница 15: ...length of the new calibration refer the picture on the right Then click Calibration meanwhile the in the toolbar should have been chosen automatically If not please choose it yourselves 3 Move the cur...

Страница 16: ...ring 1 Choose the tool you need to do measuring in the toolbar 2 Click dots or draw lines that you need to measure in the main operating window 3 Place the results of measuring in a proper place aroun...

Страница 17: ...a random rectangle in the view and the whole view would be flipped Click Left again end the special effect Capture Image 1 Click to capture 2 The result of capture can be checked and deleted in the Pi...

Страница 18: ...ll no image please check the Device Manager of your PC delete the USB Camera in the Imaging devices and rescan Let the system identifies again After all in the Imaging devices there will show another...

Страница 19: ...s name Address Phone number Post code email Model name Purchase date Fault feedback Date Fault Notice Our warranty does not cover 1 If users can not provide the purchase proof or the Warranty 2 If use...

Отзывы: