6

Image switching

When connecting the endoscope to the microscope, pay attention to the direction of the plug. Refer to

the schematic diagram in Figure9:

Note: 1.After the endoscope is connected to the main device, please do not swing left or right to

avoid poor contact of the endoscope; 2. The endoscope does not support functions such as remote

control, capture, and video recording.

(Figure9 Schematic diagram of endoscope interface)

After the endoscope is connected, its image does not appear on the screen immediately. You need to

press the "V" key (image switching key, Figure 8/

), the remote control "NTL/PAL" key has the

same function).

The process of image switching is shown in Figure 10. Through the "V" key, the endoscope image can

be switched: from small to full screen. If you don't need the endoscope image, you can continue to

press the "V" key to switch to the microscope image or not connect to the endoscope.

Press the "V" key for the first time to achieve dual-screen display; press the "V" key for the second time

to display the endoscope image; press "V" for the third time to switch to the microscope image.

(Figure10 Schematic diagram of the screen switching process)

Содержание AD206S

Страница 1: ...Digital Microscope AD206S Users Manual...

Страница 2: ...Maintenance 1 Basic Parameters 1 What s in the box 2 Installation tutorial 3 Buttons 5 Quick start 5 Image switching 6 Obtain the clear image 7 Take pictures and videos recording 7 Date and language...

Страница 3: ...alcohol 5 Keep the equipment in a clean and dry environment Keep away from oil water gas and other materials that may cause corrosion 6 The handicapped sick or allergic people are not suitable to use...

Страница 4: ...2 What s in the box Figure1 What s in the box Figure2 Endoscope accessories...

Страница 5: ...rease the image gain can block external stray light make the center of the picture brighter Side view mirror used to observe the back or side of an object For example the inner wall of the pipe Transp...

Страница 6: ...be able to not just turn the focus controller of the optical stack freely but also freely adjust the monitor the angle between the base and the optical bracket while the rest of microscope remains in...

Страница 7: ...of the switch cable underneath the display until the display turns on It may turn on automatically while connecting cables at the first time and it s totally normal Troubleshooting 1 If the device is...

Страница 8: ...not appear on the screen immediately You need to press the V key image switching key Figure 8 the remote control NTL PAL key has the same function The process of image switching is shown in Figure 10...

Страница 9: ...from the figure Buttons marked with an M can be used to cycle between three modes video standby still image and review In video standby mode there shows time 1080FHD white color font at the top right...

Страница 10: ...d for a while till options show up Date and language settings In any mode press the M button and hold it for a while until the Video Still Playback Menu shows up on the display Or you can press MENU b...

Страница 11: ...button on the monitor and hold it until the device switching off If you turn off the device by pressing the button on the switch cable or just simply cut off the power supply the setting would not be...

Отзывы: