ANDILOG CENTORMETER EASY Скачать руководство пользователя страница 11

 

Operating manual 

– V1.0 

CENTORMETER EASY 

 

 

- 10 - 

 

III.

 

 Advanced Features 

 

Access  to  the  advanced  features  configuration  mode  by pressing  the  M  button.  The  following 
screen appears: 
 

1.

 

Setting screen: 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
In the menu, the button has the following functions: 

On/Off  

Turn the gauge on or off 

ZERO   

Arrow to the left: displaces the cursor to the left 

Units   

Arrow downward: displaces the cursor to the bottom 

TDX 

 

Arrow to the right: displaces the cursor to the right and validates 

MAX   

Arrow upward: displaces the cursor to top 

 

switches to the previous screen saving modifications. 

 

Turn on the backlit. 

 

Switches to the previous screen cancelling modifications. 

 

 
To move within the menu, use “

- MAX ” and “

- UNIT ” buttons  

To select the desired function, highlight it and press the “TDX” button. 
To switch to display mode, use “M” button. 
 
In  the  following  screens,  the  operating  mode  is  the  same.  In  any  other  screen  whatever  the 
position of the cursor: 

“X”: switches to the previous screen cancelling the modifications. 
“M”: switches to the previous screen saving the modifications. 

      M E N U  
 
  C E N T O R M  
 
S C R E E N  
S Y S T E M  

 

 
 
 
 
 
 

E N D   

T D X  

Содержание CENTORMETER EASY

Страница 1: ...anual 1 0 CENTORMETER EASY Operating Manual CENTORMETER EASY V1 0 ANDILOG Technologies BP62001 13845 Vitrolles Cedex 9 France Email info andilog com Site www andilog com Ph 33 0 820 888 202 Fax 33 0 8...

Страница 2: ...Display mode 7 6 Reset function 8 7 Measure unit 8 8 Peak values 8 9 Backlight 8 10 Perform a measurement 8 III Advanced Features 10 1 Setting screen 10 2 Display 11 3 System setting 12 4 Using the R...

Страница 3: ...onnected by a wire at the bottom of the gauge The sensor can be measuring force torque linear or angular displacement CALIBRATION The CENTORMETER units are calibrated by Andilog and always delivered w...

Страница 4: ...ximum life time of the batteries It is recommended to use the original power adaptor supplied by ANDILOG Technologies The power adaptor has the following specifications 12V 1 5A b Sensor In spite of i...

Страница 5: ...resentation General view Back of the Centormeter Run down adapteur optional accessories for motorized torque tools Internal senor supply with matching square 4 fixing holes Display Power switch USB RS...

Страница 6: ...Operating manual V1 0 CENTORMETER EASY 5 Display presentation VALUE DISPLAY BACK LIGHT SETTING MODE CANCELS ACTIONS DISPLAY OF PEAK VALUES OR CALCULATIONS UNIT CHANGE ON OFF BUTTON...

Страница 7: ...e displaying low battery indication CENTORMETER gauge runs internal tests If during these tests problems are detected the internal information screen is displayed An error message indicates that the g...

Страница 8: ...displayed at any time even for additional external sensor Measure unit indicates the unit used for the display Several units are available Press the UNIT button to change the measure unit Line 1 displ...

Страница 9: ...sor s health It is possible to leave tools fixed on the force gauge but the total weight must not exceed 20 of the sensor s maximum capacity 7 Measure unit To change the unit of measure just press UNI...

Страница 10: ...um and minimum values Apply torque on your torque tools The Centometer Easy automatically display the maximum values measured on the first line and will remember it until the ZERO buttons is pressed o...

Страница 11: ...validates E MAX Arrow upward displaces the cursor to top F M switches to the previous screen saving modifications G O Turn on the backlit E X Switches to the previous screen cancelling modifications...

Страница 12: ...O VLI MXI MNI Set the display of the second line 2 None NO current value VLI Maximum MXI Minimum MNI SIGN NO TRA COM Set if the sign is displayed and if yes the direction of the positive sign tensile...

Страница 13: ...omputer the Centormeter EASY can send data according to two protocols Pressing the TDX button the Centormeter EASY send under ASCII format the maximum torque value The computer queries the Centormeter...

Страница 14: ...ou want to capture the values graph and use graphics tools CALIGRAF software goes further in tests analysis If you wish to connect your gauge to a PC via one of our programs contact your ANDILOG TECHN...

Страница 15: ...ges units Down Arrow 5 MAX Displays max and min values Up Arrow 6 TDX Sends a value through RS232 Right Arrow 7 X Inactif Returns to preceding screen without saving 8 M Setting mode Returns to precedi...

Страница 16: ...or major defect has been found In System Menu when M MAX are pressed Minor defects Low battery Expired calibration date Press MAX button to continue Major defects Damaged sensor High number of overloa...

Отзывы: