background image

2. Strip back 1-1/4” of outer sheathing, cut off any excess 

wires, shield and ground.  Strip off 1/4” insulation from 
remaining four wires.  It is not necessary or recommended 

1. Insert cable through Pressing Screw, Compression 

Ring, Seal Grommet, and Sleeve as shown below.

  CABLE REQUIREMENTS

4 conductor, stranded, 18-24 AWG, 
shielded with ground.

4-8mm (0.16-0.31”) Cable Sheath 
OD.

Shown With

Cap Removed

3. Orient Connector end so that 

center pin connecting screw is 
horizontal facing right (see 
detail). 

4. Wire PWR + (red) wire to top-right   

terminal, and PWR - (black) wire to 

    top-left terminal.  Wire LOOP + (white) to 

center terminal and LOOP - (green) to 
bottom left terminal.

5. Screw on the Sleeve.  Hand-tighten only.

6. Press the Seal Grommet into the Sleeve and 

hand-tighten the Pressing Screw against the 
compression ring.

7. Use a wrench to tighten the Pressing Screw 

another 3/4 turn.  Do not over-tighten!

Connector End

 Section 1 - Field Wireable Connector 

LN Potentiometric Level Transmitter

Quick Start Installation Guide

Rev. 2.1                                                                   Doc 1136                                                                  Page 1 of 2

Technical Bulletin

Anderson Instrument Co., Inc.

156 Auriesville Road
Fultonville, NY  12072

Phone: 518-922-5315 or 800-833-0081    
www.anderson-negele.com

To install connector, simply line up key, press 

into receptacle, and hand-tighten the 

*Receptacle pins should be coated with
 USDA approved dielectric grease to 
 Minimize possibility of corrosion.

Field Wireable Connector 

+PWR (red)  wire

-PWR (black) wire
Shield (clear or bare) wire

P/N:  42119B0000 (without cable)

P/N: 5662400000

*Dielectric Grease

Retaining Ring

Pin 1 - Red

(+PWR 18-36 VDC)

Pin 2 - Black

(-PWR)

DETAIL

Sleeve

Seal 

Grommet

Compression

Ring

Pressing Screw

-2 included choose one to accommodate cable OD

Pin 3 - Green

(LOOP- Return)

Pin 5 - White

(LOOP+)

Loop- return (green)  wire

Loop+ (white)  wire

Molded Cord Set - Heavy Duty

P/N:  42117F0025
         42117F0050
         42117F0100

Loop + (grey)  wire

Loop - (blue) wire
Shield (clear or bare) wire

PWR-  (white)  wire

PWR+ (brown)  wire

Molded Cord Set

Note: Green and White not used
on 2 wire devices.
Shield  not connected to nut.

P/N:  42117K0025
         42117K0050
         42117K0100

+PWR (red)  wire

-PWR (black) wire
Shield (clear or bare) wire

Loop- return (green)  wire

Loop+ (white)  wire

Отзывы: