E1 Single Speed Electric Motor Unit, 12V & 24V
To Suit Self-Tailing Winch Sizes 52
STEP 6
•
Measure the total wire run distance from the battery to the motor unit and back to the battery.
•
Refer to table below to determine the required motor unit to battery wire size (cross-section
area), circuit breaker/fuse size and total battery capacity (Ah).
•
Connect the motor unit to the battery bank, with the appropriate circuit breaker or fuse in the positive
power wire line. The circuit breaker or fuse should be positioned as close to the battery as possible,
in an accessible location so the switch can be turned off when not in use.
*Note:
The fuse should be a “slow blow” or “long delay” type to allow for start-up current spike.
WARNING: Do not use smaller wire than recommended in the table. This can cause malfunction
of the winch and in worst case - FIRE. The wires should always be as short as possible.
------------------------------ 12V. DC -------------------------------
------------------------------ 24V. DC -------------------------------
WINCH
WIRE
LENGTH*
WIRE
SIZE
CIRCUIT
BREAKER
ADDITIONAL
BATTERY
CAPACITY
PER WINCH
MIN. TOTAL
BATTERY
BANK
CAPACITY
WIRE
SIZE
CIRCUIT
BREAKER
ADDITIONAL
BATTERY
CAPACITY
PER WINCH
MIN. TOTAL
BATTERY
BANK
CAPACITY
52 ST E1
0-3 m / 0-10 ft
70 mm²
200 A
150 Ah
400 Ah
35 mm²
120 A
75 Ah
200 Ah
3-8 m / 10-27 ft
95 mm²
200 A
150 Ah
400 Ah
50 mm²
120 A
75 Ah
200 Ah
* Wire length = Total cable length from battery to motor and back.
INSTALLATION INSTRUCTIONS
STEP 5
•
Connect wires from push button to wires from motor unit as per electrical connection