ANDELI MCT-520DPL Скачать руководство пользователя страница 3

1 Wire Check Button
2 Welding model selection: MIG 2T/MIG 4T, Plasma CUT, HF TIG, Cold TIG, MMA
3 MIG Synergic/MIG Manual/TIG PULSE Selection: Press to select MIG Synergic mode (wire diameter) or MIG Manual mode or DC Pulse TIG
4 TIG Parameter Selection Button: Press to select different TIG parameters (move right)
5 Parameter Adjust Knob: Adjust to increase or decrease various parameters
6 TIG Parameter Selection Button: Press to select different TIG parameters (move left)
7 Function Selection Button: Press to select CO2 / mixed gas / gasless in MIG mode, or VRD in MMA mode, or 2T/4T trigger in TIG mode
8 Function Selection Button: Press to select Hot-start / Hot-start time / Arc-force in MMA mode, or Inductance in MIG mode, or 2T/4T trigger in CUT mode
9 Job Storage Button: Press to call the saved job (total 10 groups of jobs). Parameters of one job will be saved after 5 seconds without adjustment
10 Digital Display for Job Number
11 Digital Display for Current, Wire Feeding Speed, Hertz
12 Digital Display for Voltage, Pulse Width, Pulse Time
13 Gas Check Button

6.INSTALLATION INSTRUCTION

The machine is equipped with power voltage compensation device. When the power voltage fluctuates between±15% of rated voltage, it still can work normally.

When the machine is used with long cables, in order to prevent voltage form going down, bigger section cable Is suggested. If the cable is too long, it may have great affluence on
the arc-striking or other performance of cutting system, e.g. the HF arc-striking performance get weak or the system work abnormally. So cables of configured length are
suggested.

6.1  Make sure intake of the machine is not blocked or covered to avoid malfunction of cooling system.

6.2  Connect the protective gas source. The gas supply passage shall include a gas cylinder, an argon gas pressure reducing flowmeter and a gas pipe. The connecting portion of
the gas pipe shall be fastened with a hose clamp or other articles to prevent argon gas leakage and air ingress.

6.3 Ground the cables with section area no less than 6mm2 to the housing, the way is connecting screw in the back of the power source to ground device, or make sure ground
terminal of power socket is firmly connected. Both ways can be used for absolute safety.

6.4 Plug the quick plug of the loop cable into the quick socket of the welder panel with a polarity of "+" and follow The hour hand is tightened tightly, and the ground wire clamp
at the other end clamps the workpiece

6.5  When using the foot switch control, connect the two-core aviation and three-core aviation plugs of the foot switch to the three-core air socket of the local panel.

6.6 According to the input voltage level of the welding machine, connect the power line to the distribution box of the corresponding voltage level. Do not connect the wrong
voltage. Also ensure that the error of the power supply voltage is within the allowable range.

6.7 When using manual arc welding, install the electrode holder as shown. After the above work

is completed, the welder is finished. In the installation work, welding is available.

7.OPERATION INTRODUCTION

7.1 Use AC TIG welding function description:

Содержание MCT-520DPL

Страница 1: ...safe position Gases and fumes May be harmful to health Keep your head out of the gases and fumes When arc welding ventilators or air extractors should be used to avoid breathing gases Arc rays Harmful to your eyes burn your skin Wear suitable protective mask light filter and protective garment to protect eyes and body Prepare suitable protective mask or curtain to protect looker on Fire Welding sp...

Страница 2: ...HF HF TOUCH TOUCH Efficiency 80 85 80 85 80 85 80 85 Duty cycle 30 30 30 30 Power factor 0 73 0 76 0 73 0 76 0 73 0 76 0 73 0 76 Insulation Class H H H H Housing Protection IP21S IP21S IP21S IP21S Weight kg 14 8 Dimensions mm 489 210 327 5 PANEL FUNCTION INSTRUCTION 5 1 Button function Option function button When the function button is selected as CUT mode or the indicator light is CUT it can cut ...

Страница 3: ...tem e g the HF arc striking performance get weak or the system work abnormally So cables of configured length are suggested 6 1 Make sure intake of the machine is not blocked or covered to avoid malfunction of cooling system 6 2 Connect the protective gas source The gas supply passage shall include a gas cylinder an argon gas pressure reducing flowmeter and a gas pipe The connecting portion of the...

Страница 4: ...ctor in use during the welding process This operation will endanger personal safety and cause serious damage to the equipment 8 MAINTENANCE WARNING Power must be turned off for all checking and maintenance before opening the housing make sure the power plug Is disconnected 8 1 Remove dust by dry and clean compressed air regularly if welding machine is operating in environment where is polluted wit...

Страница 5: ...ator light on the panel lights up In this case you do not have to unplug the power supply so that the cooling fan can continue to work to cool the welder When the red indicator light goes out the temperature drops to the standard range and the welding can be restarted ll QUESTIONS TO BE RUN INTO DURING CUTTING The phenomena listed here may be related to the accessories gases environmental factors ...

Страница 6: ...does not light no high frequency discharge sa sa sa sound LIFT TIG welding can start arc 1 The primary line of the arcing transformer has poor contact with the power board and is retightened 2 The discharge nozzle is oxidized or the distance is remote The surface oxide film of the discharge nozzle is treated or the distance of the discharge nozzle is adjusted to 1 mm 3 The Individual components of...

Страница 7: ...s on no output 1 It may be overcurrent protection Please turn off the machine When the abnormal indicator light is off and then restarted it can be restored 2 may be overheat protection do not need to shut down for 2 3 minutes the machine can naturally return to normal 3 It may be that the inverter circuit is faulty Please unplug the power supply plug of the main transformer on the MOS board near ...

Страница 8: ... 19 Main board 2 20 Rectifier board 21 Fan 22 Read metal panel 23 Rear plastic panel down 24 Rear plastic pane l up 25 Cable clip 26 Gas connector 27 Power switch 28 Relief valve bracket 29 Handle 30 Housing 31 Side panel 32 Wire spool 33 Electronic valve 34 Wire feeder 35 Control board cover 36 Relief valve bracket Содержание Каталог радиолюбительских схем Все права защищены Радиолюбительская стр...