10)
TOKEN BRIDGE MOTOR ERROR [E.81 & 82]
▶SOLUTION
: TOKEN BRIDGE MOTOR ERROR [E.81 & 82]
1 HOW TO TEST
TEST MODE → TOKEN BRIDGE TEST→ SELECT button → SHOOTING button
2 Check internal JAM by foreign material, card, token ( P1 )
3 Check MOTOR connector connection status ( P2 )
4 Check assembly status ( P3 )
5 voltage check ( MAIN PCB / CN16 ) : PIN 1 : 11V , PIN 2 : GND
6 MOTOR replacement
7 MAIN PCB replacement
▶SOLUTION
: TOKEN BRIDGE FRONT SENSOR ERROR [E.81]
1 HOW TO TEST : TEST MODE → TOKEN BRIDGE TEST
sensor status check-Detected Sensor : " _ " / Non-Detected sensor : " 0 "
2 Check internal JAM by foreign material, card, token ( P1 )
3 SENSOR PCB wiring connection and connector connection status check ( P2 )
4 Check the sensor assembly status ( P4 )
5 voltage check ( SENSOR PCB )
: PIN 1 : 4.5V, PIN 2 : 0.5V, PIN 4 : GND ,
PIN 3 : 4.5V or more when detected / Less than 0.5V when not detected
5 SENSOR PCB replacement
6 voltage check ( MAIN PCB / CN15 )
: PIN 3: 4.5V or higher, PIN 4: less than 0.5V, PIN 7: GND
7 MAIN PCB replacement
CODE
PHOTO INT-1 PCB ASS'Y
ACIR0PCB011
MAIN PCB ASS'Y
AAV10PCB001
PART NAME
PART NAME
CODE
MOTOR
MZZZ0MOT173
CODE
PART NAME
MAIN PCB ASS'Y
AAV10PCB001
PART NAME
CODE
P3
ERROR OR LOCATION
P1
P2
P4
E82
E81
- 25 -