1. Always make sure the probe is clean and undamaged.  
2. Power on:    Press the “ON/MEM” button. 
3. Mode selection:   

 

Ear mode:   

Press the “ON/MEM” button, the default mode of thermometer is ear mode. The thermometer is can be used after 
you see  the  ear icon on the display and hear two beep sounds. In this mode, you can measure  the body 
temperature by ear measurement. 

 

Forehead mode: After power on, press and hold the “ON/MEM” button, and press the “SCAN” button one time for forehead mode. 

The forehead icon will display

 

and you will hear two beeps. In this mode, you can measure the body temperature 

by forehead measurement. 

 

Surface mode:  After power on, press and hold the “ON/MEM” button, and press the “SCAN” button one time for surface mode. 

The surface icon will display. In this mode, you can measure surface temperature of an object. 

4. Measuring temperature:  

Ear temperature measuring. Points for attention:     

(1) Gently pull the ear back to straighten the ear canal and snugly position the probe into the ear canal, 

aiming towards the membrane of the eardrum to obtain an accurate reading. 

 

(2) Press and hold the “SCAN” button until you hear a beep sound. Remove the probe from the ear and 

read the temperature measurement on the LCD. 

 

 

Pull 

 

Scan 

Содержание UT-801

Страница 1: ...on Infrared Thermometer 1WMPD4003399 Model UT 801 Instruction Manual Original ENGLISH FRAN AIS ESPA OL ITALIANO Manuel d instructions Manual de Instrucciones Manuale di Istruzioni Traduction Traducci...

Страница 2: ...Customers 2 Preliminary Remarks 2 Precautions 2 Symbols 3 Parts Identification 4 Functions 5 Installing changing batteries 7 Measurements 8 Troubleshooting 11 Care Maintenance 12 Technical Data 13 App...

Страница 3: ...of the Notified Body Environment for use This device is designed for use indoors This device the infrared ear forehead thermometer can measure the infrared heat generated by eardrum temple area and su...

Страница 4: ...inimum distance of 3 3 meters 11 feet should be kept from such devices Measurements may be distorted if the device is used close to televisions microwave ovens X ray or other devices with strong elect...

Страница 5: ...olation sheet Stand by ON MEM button Cap Display SCAN button Isolation sheet Battery cover Last memory icon Forehead icon Battery icon Memory icon Mute icon Unit icon Surface icon Ear icon Last memory...

Страница 6: ...able ambient temperature is important for the baby and patient The thermometer always helps you recognize the room temperature Surface Mode The surface mode shows the actual and undusted surface tempe...

Страница 7: ...ou can also use the same process to change from F to C Mute mode The buzzer setting defaults to on You can toggle the buzzer on off in mute mode With the power on press and hold the ON MEM button for...

Страница 8: ...he device and flip the battery out with a small screwdriver 3 Insert the new battery under the metal hook on the left side and press the right side of the battery down until you hear a click 4 Replace...

Страница 9: ...splay and you will hear two beeps In this mode you can measure the body temperature by forehead measurement Surface mode After power on press and hold the ON MEM button and press the SCAN button one t...

Страница 10: ...ometer on the temple see picture You can choose left or right temple 3 Press the SCAN button and gently scan around the temple area While scanning you will hear a beep sound which indicates the newest...

Страница 11: ...for more than 1 minute The device can only be powered off automatically In surface mode you can manually turn the power off by pressing ON MEM button for 3 seconds 2 Clean the probe after each use to...

Страница 12: ...C to 40 C 50 F to 104 F The ambient temperature is 10 C 50 F In ear forehead mode Temperature taken is higher than 42 2 C 108 F In surface mode Temperature taken is higher than 80 C 176 F Please sele...

Страница 13: ...device dry and away from any liquids and direct sunlight The probe should not be submerged into liquids NOTES The probe is the most delicate part of the thermometer Use with care when cleaning the le...

Страница 14: ...e less than 70 C RH 95 Atmospheric pressure 800 to 1013hPa Accuracy Ear Forehead mode 0 2 C 0 4 F within 35 to 42 C 95 to 107 6 F Ambient Temp 15 to 35 C 0 3 C 0 5 F for other range Surface mode 0 3 C...

Страница 15: ...Appendix EMC Information...

Страница 16: ......

Страница 17: ......

Страница 18: ......

Страница 19: ...alasia Pty Ltd 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 61 8 8301 8100 Fax 61 8 8352 7409 A D Instruments India Private Limited 509 Udyog Vihar Phase V Gurgaon 122 016 Haryana...

Отзывы: