background image

 

 

 

Wrist Digital Blood Pressure Monitor 

-

Instruction Manual 

Original 

Manuel d’instructions 

Traduction 

Manual de Instrucciones 

Traducción 

Manuale di Istruzioni 

Traduzione 

 

 

 

使用手冊

 

 

 

翻譯

 

1WMPD4003120E 

Содержание UB-525

Страница 1: ...Wrist Digital Blood Pressure Monitor Instruction Manual Original Manuel d instructions Traduction Manual de Instrucciones Traducción Manuale di Istruzioni Traduzione 使用手冊 翻譯 1WMPD4003120E ...

Страница 2: ...rement 9 Measurements 10 Recalling the Memory Data 11 Deleting Data Stored in Memory 11 What Is The IHB AFib Indicator 12 What Is The AFib 12 Pressure Bar Indicator 12 WHO Classification Indicator 13 About Blood Pressure 13 What is Blood Pressure 13 What is Hypertension and How is it Controlled 13 Why Measure Blood Pressure at Home 14 WHO Blood Pressure Classification 14 Blood Pressure Variations ...

Страница 3: ...ould be avoided Clean the device with a dry soft cloth or a cloth dampened with water and a neutral detergent Never use alcohol benzene thinner or other harsh chemicals to clean the device Avoid tightly folding the cuff for long periods as such treatment may shorten the life of the components The device is not water resistant Prevent rain sweat and water from soiling the device Measurements may be...

Страница 4: ...ear cuff may become hot and potentially cause malfunction Use of accessories not detailed in this manual may compromise safety Should the battery short circuit it may become hot and potentially cause burns Allow the device to adapt to the surrounding environment before use about one hour Do not inflate without wrapping the cuff around your wrist Contraindications The following are precautions for ...

Страница 5: ...lic pressure IHB AFib symbol Pulse rate Alkaline batteries LR03 or AAA Battery cover button average memory and change of preset parameters START button Display Cuff Heart mark Battery indicator MEMORY Average WHO classification indicator and Pressure bar indicator ...

Страница 6: ...lood pressure in mmHg PUL Pulse per minute Battery installation guide Direct current SN Serial number Date of manufacture Type BF Device and cuff are designed to provide special protection against electrical shocks EC directive medical device label IP International protection symbol WEEE label Manufacturer EU representative Refer to instruction manual booklet Keep dry ...

Страница 7: ...attery power indicator during measurement LOW BATTERY The battery is low when it blinks Replace all batteries with new ones when the indicator blinks or Unstable blood pressure due to movement during measurement Take another measurement Remain still during measurement The systolic and diastolic values are within 10 mmHg of each other Apply the cuff correctly and take another measurement The pressu...

Страница 8: ...o not mix old and new batteries It may shorten the battery life or cause the device to malfunction LOW BATTERY mark does not appear when the batteries are drained The battery life varies with the ambient temperature and may be shorter at low temperatures Generally two new LR03 AAA batteries will last approximately for four months when used twice for measurement each day Use the specified batteries...

Страница 9: ...bout the same time every day An individual s blood pressure varies constantly depending on what they are doing what they have eaten and what they drink can have a very strong and rapid effect on your blood pressure Do not measure immediately after physical exercise or a bath Rest for twenty or thirty minutes before taking the measurement Do not cross your legs Keep your feet flat on the floor and ...

Страница 10: ...stored in memory While readings are displayed if you press the button to turn the device off new readings are not stored Remove the cuff and record your data Notes The device is provided with an automatic power shut off function which stores the current data in the memory and turns the device off automatically one minute after measurement Allow at least three minutes between measurements on the sa...

Страница 11: ... device displays readings of the systolic and diastolic pressure readings pulse rate WHO classification I H B symbol The cuff exhausts the remaining air and completely deflates automatically Note If you do not want to store new readings in memory press the button while readings are displayed 5 Press the START button again to turn the device off Remove the cuff Notes The device is provided with an ...

Страница 12: ...n Data of number and measurement data The device displays in order from most recent data In the example No 30 data No 29 data No 01 data 3 If you press the button after oldest data is displayed the device proceeds to step 1 the average of all measurements and the number of data are displayed 4 Press the START button to turn the device off After one minute of non operation the device will turn off ...

Страница 13: ...tracts due to electrical signals occurring in heart and sends blood through the body Atrial fibrillation AFib occurs when the electrical signal in the atrium becomes confused and leads to disturbances in the pulse interval AFib can cause blood to stagnate in the heart which can easily create clots of blood a cause of stroke and heart attack Pressure Bar Indicator The indicator monitors the progres...

Страница 14: ...hich is measured first thing in the morning while one is still at rest and before eating What is Hypertension and How is it Controlled Hypertension an abnormally high arterial blood pressure if left unattended can cause many health problems including stroke and heart attack Hypertension can be controlled by altering lifestyle avoiding stress and with medication under a doctor s supervision To prev...

Страница 15: ...n in the chart at the right Blood Pressure Variations An individual s blood pressure varies greatly on a daily and seasonal basis It may vary by 30 to 50 mmHg due to various conditions during the day In hypertensive individuals variations are even more pronounced Normally the blood pressure rises while at work or play and falls to its lowest levels during sleep So do not be overly concerned by the...

Страница 16: ...ed properly Apply the cuff correctly You moved your wrist or body during the measurement Make sure you remain very still and quiet during the measurement The cuff position is not correct Sit comfortably and still Place your arm on a table with your palm facing upward and the cuff at the same level as your heart If you have a very weak or irregular heartbeat the device may have difficulty in determ...

Страница 17: ...sure proper functioning and accuracy Please contact the authorized dealer in your area or A D for maintenance Technical Data Type UB 525 Measurement method Oscillometric measurement Measurement range Pressure 0 299 mmHg Systolic pressure 60 279 mmHg Diastolic pressure 40 200 mmHg Pulse 40 180 beats minute Measurement accuracy Pressure 3 mmHg Pulse 5 Power supply 2 x 1 5 V alkaline batteries LR03 o...

Страница 18: ...a Dimensions Approx 56 W x 88 H x 21 5 D mm Weight Approx 90 g excluding the batteries Ingress protection IP20 Note Specifications are subject to change for improvement without prior notice IP classification is the degrees of protection provided by enclosures in accordance with IEC 60529 This device is protected against solid foreign objects of 12 mm diameter and greater such as a finger This devi...

Страница 19: ...English 18 MEMO ...

Страница 20: ...x 1 408 263 0119 A D AUSTRALASIA PTY LTD 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 61 8 8301 8100 Fax 61 8 8352 7409 OOO A D RUS OOO ЭЙ энд ДИ РУС 121357 Российская Федерация г Москва ул Верейская дом 17 Business Center Vereyskaya Plaza 2 121357 Russian Federation Moscow Vereyskaya Street 17 тел 7 495 937 33 44 факс 7 495 937 55 66 A D Technology Trading Shanghai Co Ltd 爱安德技...