background image

 

 

English  3

 

Parts Identification 

 
 
 

Proper fit range 

Index mark 

Ruber bulb 

Battery compartment 

Exhaust valve 

Display

Start button

Battery cover 

Air socket 

Air connector plug 

Battery

LR6P, R6 or AA

Air hose

Artery position mark

Arm cuff

Heart mark 

Systolic pressure 

Diastolic pressure 

Pulse rate 

Exhaust mark.   

(Exhaust air from the cuff) 

Pressure mark.   

(Pump air into the cuff) 

Battery indicator 

I.H.B. indicator   

(Irregular heartbeat indicator) 

Pressure Bar Indicator 

and 

WHO Classification Indicator 

MEMORY 

Part Of Display 

Содержание UA-705

Страница 1: ...Digital Blood Pressure Monitor Model UA 705 Instruction Manual Original Manuel d instructions Traduction Manual de Instrucciones Traducción Manuale di Istruzioni Traduzione 使用手冊 翻譯 1WMPD4000988D ...

Страница 2: ...e 10 What Is Hypertension And How Is It Controlled 11 Why Measure Blood Pressure At Home 11 WHO Blood Pressure Classification 11 Blood Pressure Variations 11 Troubleshooting 12 Maintenance 12 Technical Data 13 Dear Customers Congratulations on purchasing a state of the art A D blood pressure monitor one of the most advanced monitors available today Designed for ease of use and accuracy this device...

Страница 3: ... reusing the device confirm that the device is clean Do not modify the device It may cause accidents or damage to the device To measure blood pressure the arm must be squeezed by the cuff hard enough to temporarily stop blood flow through the artery This may cause pain numbness or a temporary red mark to the arm This condition will appear especially when measurement is repeated successively Any pa...

Страница 4: ... connector plug Battery LR6P R6 or AA Air hose Artery position mark Arm cuff Heart mark Systolic pressure Diastolic pressure Pulse rate Exhaust mark Exhaust air from the cuff Pressure mark Pump air into the cuff Battery indicator I H B indicator Irregular heartbeat indicator Pressure Bar Indicator and WHO Classification Indicator MEMORY Part Of Display ...

Страница 5: ...exhaust valve button to exhaust air from the cuff Flashes when pressure is insufficient for the measurement Pump air into the cuff with the rubber bulb Previous measurements stored in memory FullBattery Indicates remaining battery power lowBattery Blinks when battery is low Replace battery with new one when the indicator blinks Unstable blood pressure due to movement during the measurement Try the...

Страница 6: ...e device will not work When LOW BATTERY mark blinks in the display replace the battery with a new one LOWBATTERYmark does not appear when the battery is drained Battery life varies with the ambient temperature and may be shorter at low temperatures Use the specified battery only The battery provided with the device is for testing monitor performance and may have a limited life Remove the battery i...

Страница 7: ...to 32 cm Adult cuff CUF D A Arm size The circumference at the biceps Note Model UA 705 is not designed for using a small adult cuff Symbols printed on the cuff Symbols Function Meaning Recommended Action Artery position mark Set the mark on the artery of the upper arm or in line with the ring finger on the inside of the arm Index REF Catalog number Proper fit range for the adult cuff It s printed ...

Страница 8: ...asurement Do not measure immediately after physical exercise or a bath Rest for twenty or thirty minutes before taking the measurement Try to measure your blood pressure at the same time every day Measurement Operation During measurement it is normal for the cuff to feel very tight Select a measurement mode operation of the device Normal measurement with storing data Press the START button Recalli...

Страница 9: ...s the exhaust valve button to expel the air from the cuff 4 When inflation is complete deflation starts automatically and the buzzer sounds and the heart mark blinks indicating that the measurement is in progress Once the pulse is detected the mark flashes and the buzzer sounds with each pulse beat 5 When the measurement is complete the buzzer sounds and the mark is displayed The systolic and dias...

Страница 10: ...ure varies constantly depending on what you are doing and what you have eaten What you drink can have a very strong and rapid effect on your blood pressure This device bases its measurements on the heartbeat If you have a very weak or irregular heartbeat the device may have difficulty determining your blood pressure Should the device detect a condition that is abnormal it will stop the measurement...

Страница 11: ...ndcontactingyourphysicianifyouseethis indicatorfrequently About Blood Pressure What Is Blood Pressure Blood pressure is the force exerted by blood against the walls of the arteries Systolic pressure occurs when the heart contracts Diastolic pressure occurs when the heart expands Blood pressure is measured in millimeters of mercury mmHg One s natural blood pressure is represented by the fundamental...

Страница 12: ...octor s readings and provides a more accurate complete blood pressure history WHO Blood Pressure Classification Standards to assess high blood pressure without regard to age have been established by the World Health Organization WHO as shown in the chart on the right Blood Pressure Variations An individual s blood pressure varies greatly on a daily and seasonal basis It may vary by 30 to 50 mmHg d...

Страница 13: ...lood pressure The value is different from that measured at a clinic or doctor s office See Why measure blood pressure at home Other Remove the battery Re install it properly and try the measurement again Note If the actions described above do not solve the problem contact the dealer Do not attempt to open or repair this product as any attempt to do so will make your warranty invalid Maintenance Do...

Страница 14: ...1 2 2007 Data memory Last 30 measurements Operating conditions 10 C to 40 C 15 RH to 85 RH 800 hPa to 1060 hPa Transport Storage conditions 10 C to 60 C 15 RH to 85 RH Dimensions Approx 81 W x 54 H x 105 D mm Weight Approx 120 g excluding battery Applied part Cuff Type BF Useful life Device 5 years when used six times a day Cuff 2 years when used six times a day Accessories sold separately Arm siz...

Страница 15: ...don Business Park Abingdon Oxfordshire OX14 1DY United Kingdom Telephone 44 1235 550420 Fax 44 1235 550485 A D ENGINEERING INC 1756 Automation Parkway San Jose California 95131 U S A Telephone 1 408 263 5333 Fax 1 408 263 0119 A D AUSTRALASIA PTY LTD 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 61 8 8301 8100 Fax 61 8 8352 7409 ...

Отзывы: