— 4 —

Important Safety Information

•  The installation in this manual is intended 

for qualified installers, service technicians or 
persons with a similar qualified background. 
Installation must be done by qualified 
professionals and in accordance with all 
applicable codes and standards, including 
fire-rated construction.

• 

The range hood may have very sharp 
edges; please wear protective gloves if it is 
necessary to remove any parts for installing, 
cleaning or servicing. 

• 

Activating any switch to ON position before 
completing installation may cause damage or 
electric shock. 

•  Due to the size of this range hood, a two 

person installation is recommended. 

To reduce the risk of fire, electric shock, or 
injury to persons: 

•  For general ventilating use only. 

DO NOT

 use 

to exhaust hazardous or explosive materials 

and vapors. 

•  

WARNING

: To Reduce The Risk Of Fire Or 

Electric Shock, Do Not Use This Fan With Any 
Solid-State Speed Control Device.

•  The combustion air flow needed for safe 

operation of fuel-burning equipment may be 
affected by this unit’s operation. Follow the 
heating equipment manufacturer’s guideline 
and safety standards such as those published 
by the National Fire Protection Association 
(NFPA), and the American Society of Heating, 
Refrigeration and Air Conditioning Engineers 
(ASHRAE), and other local code authorities. 

•  Before servicing or cleaning the unit, switch 

power off at service panel and lock the service 

disconnecting means to prevent power from 
being switched on accidentally. When the 
service disconnecting means cannot be 
locked, securely fasten a prominent warning 
device, such as a tag, to the service panel.

•  Clean grease-laden surfaces frequently. To 

optimize performance and to disperse air 

properly, make sure to vent air outside. DO 
NOT vent exhaust into spaces between walls, 
crawl spaces, ceilings, attics or garages. 

• 

Ducted fans MUST always be vented to 
the outdoors. 

•  This unit MUST be grounded and used with 

metal ductwork only.

•  Sufficient air is needed for proper combustion 

and exhausting of gases through the duct to 
prevent back drafting. 

•  When cutting or drilling into wall or ceiling, be 

careful not to damage electrical wiring or other 
hidden utilities. 

•  All electrical wiring must be properly installed, 

insulated and grounded. 

• 

Old ductwork should be cleaned or replaced 
if necessary to avoid the possibility of a 
grease fire. 

• 

Check all joints on ductwork to ensure 
proper connection; all joints should be 
properly taped using a certified aluminum 
or foil tape.

•  Use this unit only in the manner intended 

by the manufacturer. If you have questions, 
contact the vendor. 

READ AND SAVE THESE 

INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE

Read and follow all instructions before using the range hood to prevent the risk of fire, electric shock, 
personal injury, or damage when using the range hood or appliances with the range hood. This guide 
does not cover all possible conditions that may occur. Always contact your service technician or 
manufacturer about problems that you do not understand.

Содержание WTNL430

Страница 1: ...Manual and Installation Instructions IMPORTANT SAFETY INSTRUCTIONS Carefully read the important information regarding installation safety and maintenance Keep these instructions for future reference...

Страница 2: ...ERS Start Here Safety Instructions are on pages 4 and 5 and Operating Instructions are on pages 16 17 and 20 Please perform these steps 1 Read the safety instructions 2 Read all instructions in the ma...

Страница 3: ...nstalling the Hood Mounting Bracket 12 Step 8 Installing the Upper Chimney Bracket 12 Step 9 Venting 13 Step 10 Mount Range Hood onto Wall 13 Step 11 Connect Ductwork 13 Step 12 Connect to AC 13 Step...

Страница 4: ...e service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the...

Страница 5: ...ATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be burned c DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result d Use an extinguisher ONLY...

Страница 6: ...nge hood mounting screws and anchors will not be included due to the variation of cabinetry constructions and wall material Please consult your installation specialist regarding the optimal type of mo...

Страница 7: ...3 Speeds Interference Protection Radio Frequency Interference Protected Motors Single Motor Control Touch control panel with LED Filtration Aluminum filter Illumination 2 x 2 5 W LED Fan Type Centrif...

Страница 8: ...ets 4 96 126 mm 1 3 35 mm 8 58 218 mm 7 99 203 mm 4 72 120 mm 1 5 38 mm 8 58 218 mm 7 8 200 mm 3 9 100 mm 3 9 100 mm 66 mm 8 6 220 mm 66 mm 0 78 20 mm Upper Chimney Bracket Lower Chimney Bracket Mount...

Страница 9: ...feet 1 5 m to 3 m of straight run Proper size duct work should be 6 in 15 3 cm in diameter To reach a 9 ft 2 7 m ceiling make sure hood is installed 30 inches 76 2 cm from cooking surface If you have...

Страница 10: ...commended between stove top and the bottom of range hood 30 in 76 2 cm minimum is required for gas stove tops 4 Height of hood and duct cover For the most efficient and quiet operation It is recommend...

Страница 11: ...ce the number or transitions and turns If long duct run is required increase duct size from 6 in 15 3 cm to 7 in 17 7 cm or 8 in 20 3 cm If a reducer is used install a long reducer instead of a pancak...

Страница 12: ...cooking range is necessary to install the hood turn OFF the power on an electric range at the main electrical box SHUT OFF THE GAS BEFORE MOVING A GAS RANGE STEP 7 Installing the Hood Mounting Bracke...

Страница 13: ...3 STEP 11 Connect Ductwork Attach ductwork to duct Secure the ductwork with duct tape to make sure joints are secure and air tight Do not install the duct tape too tightly as this may prevent the damp...

Страница 14: ...pe wire for the electric current This appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded WA...

Страница 15: ...r or fan seems weak Check that the duct sized used is at least 6 in 15 3 cm or 3 1 4 x 10 in 8 3 x 25 4 cm Range hood WILL NOT function efficiently with insufficient duct size For example 7 in 17 7 cm...

Страница 16: ...d Digit 3 shows on screen Indicators are ON xPress once Fan will work at 2nd speed Digit 2 shows on screen Indicators are ON yPress second time Fan will work at 1st speed Digit 1 shows on screen Indic...

Страница 17: ...reverse Filters should be cleaned after every 30 hours of use Should filters wear out due to age and prolonged use replace with a new filter u Make sure the range hood is unplugged or turn OFF breake...

Страница 18: ...valve Exhaust 7 Power cord 8 Housing assembly 9 Cover of switch box 10 Switch board 11 Front panel 12 Rear bracket 13 Base of electronic box 14 PCB 15 Capacitor 16 Cover of electronic box 17 Blower as...

Страница 19: ...s PCB u v y x w u v w x Number Part 1 Grid 2 Motor 3 Impeller 4 Blower 5 Wind drum inlet Electrical Assembly u v w Blower Assembly Number Part 1 Grid 2 Motor 3 Impeller 4 Blower 5 Wind drum inlet u v...

Страница 20: ...perating For optimal operation clean range hood and all baffle spacer filter grease tray oil container regularly Regular care will help preserve the appearance of the range hood Cleaning Exterior Surf...

Страница 21: ...r your product warranty by visiting the Ancona Home website Canada USA Phone 1 888 686 0778 Fax 800 350 8563 Email service anconahome com Website www anconahome com Ancona is in association with Mr Ap...

Страница 22: ...22 Notes...