— 14 —
STEP 12
Connect Ductwork
•
Attach ductwork to damper. Secure the ductwork with duct tape to make sure joints are secure and air- tight.
• Do not install the duct tape too tightly as this may prevent the damper flaps from opening which will overwork the motor
and cause improper functioning of the unit.
•
Fasten all connections with sheet metal screws and tape all joints with certified aluminum or foil tape. Use caulking to
seal exterior wall or roof opening around the cap.
STEP 13
Connect to AC
•
Connect AC plug into a grounded AC outlet
having 120V, 60Hz. Place the outlet at a maximum
distance of 33-1/2” (851 mm) from where the cord
exits on the hood.
3-Pronged Plug
Ground Plug
3-Prong Receptacle
IMPORTANT:
• Observe all governing codes and ordinances.
•
It is the customer’s responsibility to contact a qualified electrical installer.
• If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that
the ground path is adequate. A 120-Volt, 60 Hz, AC-only, fused electrical supply is required on a separate 15-amp
circuit, fused on both sides of the line.
• DO NOT ground to a gas pipe.
• Check with a qualified electrician if you are not sure that the range hood is properly grounded.
• DO NOT have a fuse in the neutral or ground circuit.
IMPORTANT: Save this Installation Guide for electrical inspector’s use.
GROUNDING INSTRUCTIONS:
• This appliance must be grounded. In the event of an electrical short-circuit, grounding reduces the risk of electric
shock by providing an escape wire for the electric current.
• This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged
into an outlet that is properly installed and grounded.
WARNING:
Improper grounding can result in a risk of electric shock.
• Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to
whether the appliance is properly grounded. DO NOT use an extension cord. If the power supply cord is too short,
have a qualified electrician install an outlet near the appliance.
• The range hood must be connected with copper wire/plug only. The range hood should be connected directly to
the fused disconnect (or circuit breaker) box through flexible armored or non-metallic sheathed copper cable. UL/
CSA listed strain relief must be provided at each end of the power supply cable.
Installation