NATURAL GAS
NATURAL GAS NOZZLES
BURNER
POSITION
NOZZLE
DIAMETER
MINIMUM
PRESSURE
MAXIMUM
PRESSURE
RATE (BTU/H)
Auxiliary
Front Right
1 x 1.10
4”
14”
5,000
Semi-Rapid
Rear Left & Right
1 x 1.29
4”
14”
7,000
Rapid
Front Left
1 x 1.45
4”
14”
8,500
Triple Ring
Center
5 x 0.99
4”
14”
18,000
LIQUID PETROLEUM (LP) GAS
LIQUID PERTROLEUM (LP) GAS NOZZLES
BURNER
POSITION
NOZZLE
DIAMETER
MINIMUM
PRESSURE
MAXIMUM
PRESSURE
RATE (BTU/H)
Auxiliary
Front Right
1 x 0.70
10”
14”
4,800
Semi-Rapid
Rear Left & Right
1 x 0.80
10”
14”
6,500
Rapid
Front Left
1 x 0.89
10”
14”
8,500
Triple Ring
Center
5 x 0.56
10”
14”
15,500
•
Contact your local gas supplier if you are not sure about the inlet pressure.
BURNER INPUT REQUIREMENTS:
Input ratings shown on the model/serial rating plate are for elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings are reduced at a rate of 4% for each 1,000 ft
(304.8 m) above sea level (not applicable for Canada).
GAS SUPPLY PRESSURE TESTING:
Line pressure testing above ½ psi gauge (14" WCP):
The range and its individual shutoff valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of ½ psi (3.5
kPa).
Line pressure testing at ½ psi gauge (14" WCP) or lower:
The range must be isolated from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psi (3.5 kPa).
16