Страница 1: ... Manual and Installation Instructions IMPORTANT SAFETY INSTRUCTIONS Carefully read the important information regarding installation safety and maintenance Keep these instructions for future reference MAAN1572 02 2020 11 24 ...

Страница 2: ...MERS Start Here Safety Instructions are on pages 4 and 5 and Operating Instructions are on pages 16 17 and 20 Please perform these steps 1 Read the safety instructions 2 Read all instructions in the manual BEFORE operating the range hood 3 Remove all packing materials 4 Installation is to be done by a qualified technician only However the ultimate responsibility for proper installation falls to th...

Страница 3: ...allation Guidelines 10 Step 6 Preparations 12 Step 7 Installing the Hood Mounting Bracket and Hood 12 Step 8 Connect Ductwork 13 Step 9 Connect to AC 13 Step 10 Install Chimney 14 Step 11 Install Grease Tunnel 14 Step 12 Install Filters 15 Installation Overview 15 Operation 16 Power Settings 16 Lights 16 Troubleshooting 16 Maintenance 17 Replacing the Light Pucks 17 Cleaning Filters 17 Range Hood ...

Страница 4: ...he service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Clean grease laden surfaces frequently To optimize performance and to disperse air properly make sure to vent air outside DO NOT vent exhaust into spaces between walls crawl spaces cei...

Страница 5: ...UATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be burned c DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result d Use an extinguisher ONLY if 1 You know you have a Class A B C extinguisher and you already know how to operate it 2 The fire is small and contained in the area where it is started 3 The fire department is being called 4 You ...

Страница 6: ...hors will not be included due to the variation of cabinetry constructions and wall material Please consult your installation specialist regarding the optimal type of mounting screws and wall anchors to suit your home s construction 10 1 Handle screws Hood mounting bracket Grease tunnel 6 1 Screws A 6 1 Screws B 5 Handles Ducting transition Chimney mounting bracket ...

Страница 7: ... Speed Control Levels 4 Speeds Interference Protection Radio Frequency Interference Protected Motors Twin Motor Control Rotary switch Filtration Baffle filter Illumination 2 1 5 W LED lights Fan Type Single chamber quiet Venting Size Top 7 75 inches 19 7 cm round 25 5 cm 10 in 40 cm 15 75 in 52 2 cm 20 5 in 75 6 cm 29 75 in 89 5 cm 35 2 in 5 2 cm 2 in 33 1 cm 13 in 35 70 cm 13 75 27 5 in ...

Страница 8: ...mounting bracket 0 2 in 0 6 cm 0 7 in 1 8 cm 0 31 in 0 8 cm Ø 0 2 in 0 6 cm 0 39 in 1 cm 2 2 in 5 6 cm 1 3 in 3 5 cm 0 39 in 1 cm 4 7 in 12 cm 8 9 in 22 8 cm 10 2 in 26 cm 34 8 cm 13 7 in 39 5 cm 15 5 in Chimney mounting bracket ...

Страница 9: ... feet 1 5 à 3 0 m of straight run Proper size duct work should be 8 in 20 3 cm in diameter To reach a 9 foot 2 74 m ceiling make sure hood is installed 31 5 inches 80 cm from cooking surface If you have a ceiling greater than 9 ft 2 74 m please visit anconahome com to order a chimney extension If ductwork is already installed ensure ductwork is free from debris and measures 8 in 20 3 cm 1 in 2 5 c...

Страница 10: ...61 cm to 76 2 cm is recommended between stove top and the bottom of range hood 30 in 76 2 cm minimum is required for gas stove tops 4 Height of hood and duct cover For the most efficient and quiet operation It is recommended that the range hood be vented vertically through the roof through 8 in 20 3 cm or bigger round metal aluminum vent work The size of the vent should be uniform Use no more than...

Страница 11: ...ps ALWAYS when possible reduce the number or transitions and turns If long duct run is required increase duct size from 8 in 20 3 cm to 9 in 22 8 cm If a reducer is used install a long reducer instead of a pancake reducer Reducing duct size will restrict airflow and decrease airflow thus reduce duct size as far away from opening as possible If turns or transitions are required install as far away ...

Страница 12: ...l box SHUT OFF THE GAS BEFORE MOVING A GAS RANGE STEP 7 Installing the Hood Mounting Bracket and Hood Using references in Height Clearance on Page 10 and Measurements and Diagrams on Page 7 and 8 use a pencil to mark the leveling point of the hood Position two mounting screws on the wall leaving 1 8 in space away from the wall Position the chimney mounting bracket directly above the hood mounting ...

Страница 13: ...dentally STEP 9 Connect to AC Connect AC plug into a grounded AC outlet having 120 V 60 Hz Place the outlet at a maximum distance of 33 1 2 in 851 mm from where the cord exits on the hood 3 Pronged Plug Ground Plug 3 Prong Receptacle IMPORTANT Observe all governing codes and ordinances It is the customer s responsibility to contact a qualified electrical installer If codes permit and a separate gr...

Страница 14: ... the risk of electric shock by providing an escape wire for the electric current This appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded WARNING Improper grounding can result in a risk of electric shock Consult a qualified electrician if the grounding instructions are not completely underst...

Страница 15: ... and insert one end of the filter into the upper channel of the range hood Figure 9 Raise the other end towards the inside of range hood rotate and insert in the bottom end of opening Figure 10 and 11 Release the handle once the filter fits into a resting position Repeat to install all filters Figure 10 Figure 9 Figure 11 Installation Overview B A ...

Страница 16: ... the blower is on The range hood might not have been secured properly on to the ceiling or wall The blower or fan seems weak Check that the duct sized used is at least 8 in 20 3 cm or 3 1 4 10 in 8 3 25 4 cm Range hood WILL NOT function efficiently with insufficient duct size For example 9 in 22 8 cm duct over 8 in 20 3 cm hole and loosely secured Check if duct is clogged or if damper unit half ci...

Страница 17: ...ker and range hood to test for operation IMPORTANT ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY AT THE MAIN PANEL BEFORE CARRYING OUT ANY OPERATION ON THE APPLIANCE Figure 12 Figure 13 Cleaning Filters IMPORTANT Drain oil from baffles spacers filters oil tunnels oil containers before oil and residue overflow Remove all baffles spacers filters grease tray and oil containers and discard oil and residue ...

Страница 18: ...umber Part 1 Hood casing 2 Hood mounting bracket 3 Transition 4 Power cable 5 Top panel 6 Blowers 7 Rotary switch 8 LED light 9 Light panel 10 Oil tunnel 11 Baffle filter 12 PCB box 13 Chimney set u v w x y U V W X at ak al am ...

Страница 19: ...r Part 1 Motor 2 Air chamber 3 Squirrel cage 4 Locknut 5 Safety screen Number Part 1 Screws 3 16 in 3 8 in 2 Electrical box cover 3 Processor board 4 Screws 3 16 in 3 8 in 5 Electrical box base 6 Electrical panel 7 Capacitor 8 Screws 3 16 in 3 8 in 9 LED light transformer ...

Страница 20: ...operating For optimal operation clean range hood and all baffle spacer filter grease tray oil container regularly Regular care will help preserve the appearance of the range hood Cleaning Exterior Surfaces Clean periodically with hot soapy water and clean cotton cloth DO NOT use corrosive or abrasive detergent e g Comet Power Scrub EZ Off oven cleaner or steel wool scoring pads which will scratch ...

Страница 21: ...me com Website www anconahome com Ancona is in association with Mr Appliance for all after sales service calls Please contact their service provider or visit their website Phone 888 998 2011 Website www mrappliance com 2020 Copyright of Ancona Home All rights reserved This material may not be reproduced displayed modified or distributed MAAN1572 02 ...