GENERAL INSTALLATION INSTRUCTIONS 

PREPARATION 

A: GENERAL 

Carefully unpack the hood but do not remove any

protective film until after installation to avoid

accidental damage or scratching. Place filters

somewhere safe for the same reason.

Check for damage, and lay out the hood pieces and

parts.

Range hoods do not come with wall or ceiling screws,

as the type of structure determines the type of screws.

 

Check that you have the right tools. In addition to

marking and measuring tools, a hammer, screwdrivers,

pliers and scissors, you may need sheet metal sheers,

and wire strippers. Safety glasses are recommended.

B: ELECTRICAL CONNECTION 

This range hood must be grounded. If the dwelling

wiring is not 2-wire with a ground wire, a ground must

be provided by the installer.

Install a 5.08 X 10.16 cm (2” X 4”) wall outlet box and

3-blade 125 Volts, 15 amp grounded receptacle.

Use wire nuts to connect incoming ground, neutral and

hot.

Push wires into the junction box and replace cover. Be

sure wires are not pinched.

C- INSTALLATION DISTANCE FROM TOP OF 

RANGE 

Hood should be placed at a minimum of:

61 cm (24

”) for electric cooking surface

 

76 cm (30”

) for gas cooking surface

4