background image

4

User manual – Pengy Pro Seat

4

www.anatomicsitt.com  | +46 11 16 18 00

Mounting the headrest

Mount the main support bracket with lever handle (B) and its washer and screw 
(A)� Note that the screw (A) should not be to tightened, it shoulde be possible to 
move up and down when the lever knob (B) is loosened�

Height adjusting the headrest

To adjust the height of the headrest, loosen the lever handle (B) and move the 
headrest to desired position� Then tighten lever handle (B)�

Angle adjusting the headrest

When adjusting the 3-joint headrest, loosen the screw (C) in the joint you
wish to adjust� Once you reach the desired position, tighten the screw (C) again�

Adjusting the headrest plate sideways

Loosen the screws (D)� Adjust the headrest plate to desired position and tighten 
the screws (D) again�

Headrest

Lever handle (B)

Screw (A)

E

(C)

(D)

Содержание Zitzi Pengy

Страница 1: ...User manual Zitzi Pengy Pro Seat EN 2020 01 08 ...

Страница 2: ...wn adjustment 8 Rotating the armrest plate 8 Table solid 9 Mounting the table 9 Crossbar 10 Installation of crossbar 10 Hip support 11 Mounting of hip support 11 Sun cover 11 Mounting of sufflett 11 Chest harness 12 Mounting of upper support bracket 12 Mounting on Pengy sulky 13 Mounting on Pengy sulky 13 Unmounting from Pengy sulky 13 Advanced footrest 14 Mounting and adjusting 14 Calf support ad...

Страница 3: ...please contact Anatomic SITT AB Correspondence Zitzi Pengy and its accessories are CE marked products A unique serial number is located on a label placed on the back or under the seat This serial number should be quoted in any correspondence regarding the product Crash tested The Pengy seating system is crashtested and approved together with the Pengy sulky according to ISO 7176 19 Check the check...

Страница 4: ...justing the headrest To adjust the height of the headrest loosen the lever handle B and move the headrest to desired position Then tighten lever handle B Angle adjusting the headrest When adjusting the 3 joint headrest loosen the screw C in the joint you wish to adjust Once you reach the desired position tighten the screw C again Adjusting the headrest plate sideways Loosen the screws D Adjust the...

Страница 5: ...nt key and then adjust it to desired height When you are satisfied with the setting tighten the screws A again Adjustment of lateral support To width and height adjust the lateral supports loosen the knobs B and then adjust to the desired height and width Tighten the knobs B when you reach the desired position Adjusting the back angle To adjust the angle of the back first loosen lever C press the ...

Страница 6: ... the color code of the seat depth and adjust the seat pocket to the desired position Tighten the screws B Seat part Size label Colour code Seat pocket plate A B Note You don t have to remove the screws completely to adjust just loosen them slightly Tip To get a good starting point for setting the seat depth the color scale on the seatbase and depth adjustment plate can be used as a guide For examp...

Страница 7: ...User manual Pengy Pro Seat Adjusting the hip belt When mounting the hip belt in the hip belt tracks use a tri glide buckle For assembly according to the tri glide method see picture Hip belt Hip belt tracks Standard positionons of hip belt ...

Страница 8: ...tment remove the screw A and turn the angle bracket 180 then tigthen the screws A Height adjustment Angle adjustment up down To adjust the height of the armrest loosen the lever handle A and move the armrest to the desired height and angle then tighten lever handle A Lateral adjustment angle To adjust the height of the armrest loosen the screws B and rotate the armrest to the desired position then...

Страница 9: ... Seat Locking lever Mounting the table Put the table on the armrest plates and then rotate the locking lever of the table into position below the armrest plate The locking lever must be rotated until it is inside the rim of the raised armrest plate Table solid ...

Страница 10: ...ates with the supported screws and fittings with grooves C The bow is pushed in and tightened with knob B on both sides The crossbar can be pulled out on the left side and rotaded away while the right side is still remains in the fitting pipe Crossbar A B C Loosen the knobs in the mounting bracket under the armrest plates Insert the bow and lock the knobs ...

Страница 11: ...using the carriage bolt A and the knob B To adjust the hip support in width loosen the knob B adjust to the desired position and lock the knob Hip support Carriage bolt A Knob B Mounting of sun cover Loosen the screws A and insert the latch pins B into the groove C Adjust to correct height and tighten the screws The sun cover can be removed from the bracket by loosening the knob D and pulling the ...

Страница 12: ... vertical head stay Lock the screw A When installing the chest harness attach the upper mounting straps in the 725 buckle Lower stripes are mounted in the groove C using a tri glide buckle To adjust the width of the harness you need a Phillips screwdriver and a wrench in size 8 B Chest harness Screw A Phillips screw and nut M5 B C D ...

Страница 13: ...hen the seat reach the lowest point in the bracket Unmounting from the Pengy sulky To unmount Pengy seat from Pengy sulky first loosen the locking pin A by pulling it out and turning it 90 When the locking pin is loosened lift the armrests up wards Mounting on Pengy sulky Note The seat can be mounted both forwards and backwards according to the desired needs Note The locking pin must always be in ...

Страница 14: ...he foot rest with the locking screw Knee joint angle adjustment B Release the knob B and then adjust to the desired angle Lock the knob when the desired angle is reached Note After adjustment the tags must go in each other so it locks Tighten the screw hard Adjustment of ankle angle C Loosen the screw and adjust the angle Lock the screw when correct angle is reached Height adjustment of foot plate...

Страница 15: ...ing is achieved Loosen the screws B to adjust the width of the calf support plates Tighten the screws when correct setting is achieved A B Adjusting wrench Calf support for advanced footrest The footplate is prepared for mounting of ankleholder Mounting of ankleholders are done under the footplate through the holes Make sure that the pad does not fold on the ankleholder Ankleholder ...

Страница 16: ...he footplate is prepared for mounting of foot straps Mounting the foot straps on all footplates is done by pulling the strap down and up through two of the pre drilled holes in the footplate The foot strap can be mounted in the front or rear hole sets Foot strap alt hole ...

Страница 17: ... can be dried in a drying cupboard Follow the directions on the respective laundry label The same washing rules applies to positioning harnesses and hip belts from Anatomic SITT AB Tools The tool 4 mm hexagon key you need to make adjustments is integrated in the the top of the profile of the backrest on the chair Maintenance instructions Check the condition regularly and perform maintenance when n...

Страница 18: ...termine if it is an adaptation or a customization An adaptation is any change made in comprehension of the CE mark All other changes are customizations Adaptations must only be made by a person deemed to be qualified for the task and should always be made in a professional manner The CE mark means that the product fulfils all of the essential European safety requirements Note that a risk assessmen...

Страница 19: ...documentation This is so that you can track the shipment should anything occur during transport Returning products In the event of faulty orders or deliveries the products should be returned within 20 days from delivery Always attach a copy of both the packing slip and the invoice Provide your reason for returning the products Make sure that you pack the product well to protect it from shocks duri...

Страница 20: ...5 86 17 01 75 Anatomic SITT AB manufacturer Box 6137 SE 600 06 Norrköping Sweden Phone 46 11 16 18 00 Fax 46 11 16 20 05 Street address Terminalgatan 1 SE 602 29 Norrköping Sweden Anatomic SITT Nederland BV Postbus 6027 4000 HA Tiel Netherlands Phone 31 344 63 45 40 Fax 31 344 62 33 61 DK SE NL Rehaco OY Haaransuontie 6 A7 90240 Oulu Finland Phone 35 840 775 22 88 FI ...

Отзывы: