9-

 

+

Set the clock and increase time. 

10-

 

A/M

The switch of manual mode and automatic mode.

 

11-

 

-

Set the clock and decrease time.   

 

. Instructions for manual operation: 

‹

 

Press “

ON/OFF

” key to make the power on and the control system is ready to run.

 

‹

 

Press “

A/M

” to start the manual mode (the indicator light on it is off). In manual mode, press 

ON/OFF

” key to turn on and turn off the circulating pump.   

‹

 

Press the “

LAMP

” key to make the underwater light on (the indicator light on it will be on).

 NOTE

Press all the above keys again to make the functions off.   

 

. Instructions for automatic operation: 

‹

 

Press “

ON/OFF

” key to make the power on and the control system is ready to run. 

‹

 

Press “

A/M

” to start the automatic mode (the indicator light on it will show RED). 

‹

 

In automatic mode, when the current time is during the period of set time, the indicator light on 

T/ON

” will be on; when the current time is out of the period of set time, the indicator light on 

T/OFF

” will be on; 

‹

 

When the manual mode is cancelled, the circulation system will be controlled by the preset time in 
each use. 

1.

 

Set system clock:

 Long press

 “A/M”

 key for 3 seconds and loosen the hand, the panel will display 

system clock time and hour/minute digit flashes: Press 

“+”“-”

 to adjust the clock time. It will store 

and return to the previous working status after flashing 3 seconds. 

 
2.

 

Setting the first operating period: 

in automatic mode, press “

T1

” key to starting setting the first on 

operating period.   

 

¾

 

Press “

T/ON

” key (the indicator light on it will be on) within 3 seconds after press “

T1

” key to start 

setting the starting time for the first period. Press “

” and “

” keys to adjust the minute (the minute 

number on LED screen will flash) within 3 seconds after press “

T/ON

” key. No action within 3 

seconds, the minute number will stop flashing and be saved automatically. If need to adjust the hour, 
press “

T1

” key again within 3 seconds to start setting it. Press “

” and “

” keys to adjust the hour 

(the hour number on LED screen will flash). No action within 3 seconds, the minute number will stop 
flashing and be saved automatically.   

¾

 

Press “

T/OFF

” key (the indicator light on it will be on) to start setting the end time within 3 seconds. 

Press “

” and “

” keys to adjust the minute (the minute number on LED screen will flash). No 

action within 3 seconds, the minute number will stop flashing and be saved automatically. If need to 
adjust the hour, press “

T1

” key again with 3 seconds to start setting the hour. Press “

” and “

” 

keys to adjust the hour (the hour number on LED screen will flash). No action within 3 seconds, the 
minute number will stop flashing and be saved automatically. 

 

PLEASE SET T2 AND T3 OPERATING PERIOD LIKE ABOVE OPERATION. 

  

REMARK: if no need to set the time in any of the 3 periods, just set the time to “zero” in that period to 
avoid it. 

 
 

Cautions before first using: 

‹

 

Before running the device for the first time, turn on the ball valve of the pipe and fill water until the 
equipment box pipe are full of water and then turn off the ball valve. 

‹

 

When it is ready to start running, press the

 “ON/OFF”

 key on control panel for several times until 

the circulation pump can work normally because there may be some air inside the pipes and pump for 
first runnin

g.  

 

Содержание WTP-25

Страница 1: ...USER MANUAL FOR WTP 25 POOL FILTER 1 WTP 25 POOL FILTER INSTALLATION OPERATION MANUAL...

Страница 2: ...It includes 1 circulating pumps 25m3 h and the pipe which connects to the Filter Area And the ozonater pipe is also in the area Swimming pool water goes into the 1 skimmer active door of the filter ar...

Страница 3: ...ol Technical specification Power supply 220V 50Hz Underwater light 18w 12V Power consumption 1 6kw Pump outlet 40mm Flow rate 25cbm h Pump inlet 40mm Ozone Generator 500mg h Dimension 1540 760 1020mm...

Страница 4: ...rol panel 1 ON OFF Control the power on and off In manual mode it also controls the ON and OFF for circulation pump 2 LAMP Turn on and turn off the underwater light 3 O3 Manual control the ON and OFF...

Страница 5: ...ght on it will be on within 3 seconds after press T1 key to start setting the starting time for the first period Press and keys to adjust the minute the minute number on LED screen will flash within 3...

Страница 6: ...let valve and fill with water or start stop the pump a few times to flush out the air Pump is working but the water flow is small Filter bag is dirty Clean filter bag Filter basket is blocked Clear ou...

Страница 7: ...ntenance and repair Please read this manual before maintenance and repair z Please contact the manufacture or the nearest dealer when there is incorrect operation or damage 2 NOTES FOR INSTALLATION AN...

Отзывы: