Analytic Systems VTC1015 Series Скачать руководство пользователя страница 3

3

VOLTAGE CONVERTERS

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

 — This manual contains important safety and operating 

instructions for the voltage converter

VOLTAGE CONVERTER PRECAUTIONS

1.  Do not expose the voltage converter to rain or snow unless it is a sealed model.
2.  Use of an attachment not recommended or sold by the manufacturer may result in a 

risk of fire, electric shock, or injury to persons.

3.  Do not disassemble the voltage converter. If service or repair is required, return it to 

the manufacturer or an authorized service center. Incorrect reassembly may result in 

a risk of fire or electric shock. Voltages up to 350 volts are present inside the voltage 

converter any time it is connected to input power, even if it is switched OFF.

4.  To reduce risk of electric shock, disconnect the voltage converter from the input 

power before attempting any maintenance or cleaning. Switching the voltage con-

verter to OFF will not reduce this risk.

5.  Never place the voltage converter directly above a battery; gasses from the battery 

will corrode and damage the voltage converter.

6.  Never allow battery acid to drip onto the voltage converter. 

Medical Equipment Notice

Analytic Systems does not recommend the use of their products in life support 

applications where failure or malfunction of this product can be reasonable 

expected to cause the failure of the life support device or to significantly affect 

its safety or effectiveness. Analytic Systems does not recommend the use of its 

products in direct patient care. 

Examples of devices considered to be life support devices are: neonatal oxygen 

analyzers, nerve stimulators (whether used for anesthesia, pain relief, or other 

purposes), auto-transfusion devices, blood pumps, defibrillators, arrhythmia 

detectors and alarms, pacemakers , hemodialysis systems, peritoneal systems, 

neonatal ventilator incubators, ventilators for both adults and infants, anesthesia 

ventilators, and infusion pumps as well as any other devices designated as 

“critical” by the U.S. FDA. 

Содержание VTC1015 Series

Страница 1: ...Series Voltage Converter 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 Registered Company Battery Chargers Inverte...

Страница 2: ...Revised Feb 2 2018 Copyright 2005 2016 Analytic Systems Ware 1993 Ltd...

Страница 3: ...voltage con verter to OFF will not reduce this risk 5 Never place the voltage converter directly above a battery gasses from the battery will corrode and damage the voltage converter 6 Never allow bat...

Страница 4: ...r and reliability in a compact package and additional input and output filtering reduce EMI to extremely low levels protecting sensitive electronics from interference A bright LED indicator panel show...

Страница 5: ...Panel 5 On Off Toggle Switch 6 Chassis Grounding Stud Front Panel Box Contents The box you have received should contain the following One VTC1015 Voltage Converter This manual One Warranty Card If an...

Страница 6: ...efer to the specifications table for the correct sizing of the circuit breaker in the distribution panel A ground stud is provided to bond the chassis to local ground to reduce or eliminate EMI OUTPUT...

Страница 7: ...e output voltage 1 At the load attach a good quality voltmeter or multimeter to monitor the voltage 2 Loosen and remove the two screws holding the cover panel to the chassis 3 Remove the cover plate t...

Страница 8: ...e next to the relay K1 as is shown in the above diagram Simply move the jumper to the desired position as is shown in the above diagram Replace the cover and re install the eight cover screws Reconnec...

Страница 9: ...re for the total output capability of all the supplies running in parallel Repeat the above steps for the negative terminals using the same gauges of black wire These units should now load share you c...

Страница 10: ...Batt 3 Turn the unit ON Battery Backup Option B 27 2V 1A Charger In Out Main PCB Chassis DC Output 28V Battery To Load 27 2V Batt Batt OP OP The Battery Backup circuit is designed so the battery is n...

Страница 11: ...nt the unit for better airflow and ventilation Input fuses blown when unit is turned ON The power source may be connected to the unit with the wrong polarity FIX Reverse the polarity of the power sour...

Страница 12: ...ient Response 2V for 50 Surge Output Amps 2 Efficiency 85 maximum output Temp Range 25 to 40 deg C maximum output Isolation Input Output Input Case 1500 Vdc 500 Vdc 24 V In Output Case 500 VDC 1500Vdc...

Страница 13: ...ng will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed o...

Страница 14: ...ms com support warranty registration DESIGNED AND MANUFACTURED BY 800 668 3884 604 946 9983 sales analyticsystems com www AnalyticSystems com 8128 River Way Delta BC V4G 1K5 Canada Battery Chargers In...