Troubleshooting

This unit provides LED indicators and a buzzer to help diagnose any problems. The unit should 

sound the buzzer to alert you prior to shutting itself down. You should immediately check the 

indicators to determine the cause of the shutdown.

OVERLOAD

Indicates that the output current has exceeded the continuous rating of the unit.

LOW OUTPUT

Indicates that the output voltage is below normal because:
The current demanded by the devices connected to the unit exceeds the 
maximum output current rating, causing the output voltage to drop to maintain 
the current at the maximum level,
The input voltage is not high enough for unit to operate.

LOW INPUT

Indicates that the input voltage is below normal because:
The input voltage is not in the correct range for proper operation of the unit.

OVERTEMP

Indicates that the Battery Charger is running too hot because:
Too much power is being drawn, turn off or unplug some devices.
The Battery Charger is located in a poorly ventilated area.

If the load exceeds the continuous rating for too long a period, the temperature sensor inside 

the unit will turn off the outputs. After the unit cools sufficiently, it will automatically come 

back on. If this happens frequently, remount the unit for increased airflow so it cools better.

Содержание VTC1000 Series

Страница 1: ...es Voltage Converter 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers I...

Страница 2: ...Revised Dec 18 2017 Copyright 2005 2017 Analytic Systems Ware 1993 Ltd...

Страница 3: ...voltage con verter to OFF will not reduce this risk 5 Never place the voltage converter directly above a battery gasses from the battery will corrode and damage the voltage converter 6 Never allow bat...

Страница 4: ...The VTC1000 Series Voltage Converter supplies either 12 24 32 or 48 VDC from a 110 250 or 300 VDC power source Other input voltages up to 300 volts or output voltages up to 48 volts are also availabl...

Страница 5: ...Inch 2 5 cm all around Material Marine Grade Aluminum Finish Black Anodized Fastenings 18 8 Stainless Weight 12 lbs 5 5 kg Specifications subjects to change without notice Actual startup is at 22 42 o...

Страница 6: ...ing of the circuit breaker in the distribution panel A ground stud is provided to bond the chassis to local ground to reduce or eliminate EMI OUTPUT CONNECTIONS Two Positive output terminals and two N...

Страница 7: ...or meters away LOAD SHARE OPTION The units may be configured for load sharing if they are equipped with the optional output isolation diodes To confirm that your unit has these diodes use an ohmmeter...

Страница 8: ...e next to the relay K1 as is shown in the above diagram Simply move the jumper to the desired position as is shown in the above diagram Replace the cover and re install the eight cover screws Reconnec...

Страница 9: ...Batt 3 Turn the unit ON Battery Backup Optional 27 2V 1A Charger In Out Main PCB Chassis DC Output 28V Battery To Load 27 2V Batt Batt OP OP The Battery Backup circuit is designed so the battery is no...

Страница 10: ...tage to drop to maintain the current at the maximum level The input voltage is not high enough for unit to operate LOW INPUT Indicates that the input voltage is below normal because The input voltage...

Страница 11: ...ng will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed o...

Страница 12: ...ms com support warranty registration DESIGNED AND MANUFACTURED BY 800 668 3884 604 946 9983 sales analyticsystems com www AnalyticSystems com 8128 River Way Delta BC V4G 1K5 Canada Battery Chargers In...

Отзывы: