Страница 3: ...ND AC POWER CORD CONNECTION INSTRUCTIONS The plug must be plugged into an outlet that is properly installed and grounded in accordance with al local codes and ordinances DANGER Never alter AC cord or plug provided if it will not fit outlet have proper cord installed by a qualified electrician Improper connection can result in a risk of an electric shock Analytic Systems does not recommend the use ...

Страница 4: ...f the plug and strip the wires as necessary The wire colours are Brown AC Hot Phase 1 Blue AC Neutral Phase 2 Green Yellow Ground All connections should be made inside an appropriate junction box The maximum current draw from the 110 VAC supply is 16 2 amps so a 20 amp circuit breaker should be used in the circuit panel and for a 220 VAC supply 8 1 amps is the maximum current draw so a 10 amp circ...

Страница 5: ...lli Volts Transient Response 1 V for 50 surge Efficiency 80 maximum output Temp Range 20 to 50 deg C maximum output Isolation Input Output Input Case 1500 Vdc Output Case 500 VDC 1500Vdc 48 V Out Isolation Output Case 500VDC Length 17 0 in 43 2 cm Width 8 2 in 20 8 cm Height 3 95 in 10 cm without carrying handle Clearance 1 Inch 2 5 cm all around Material Marine Grade Aluminum Finish Black Powder ...

Страница 6: ...cause The input voltage is not in the correct range for proper operation of the unit OVERTEMP Indicates that the power supply is running too hot because Too much power is being drawn turn off or unplug some devices The power supply is located in a poorly ventilated area OVERLOAD Too much power is being drawn turn off or unplug some devices If the load exceeds the continuous rating for too long a p...

Страница 7: ...ing will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed or altered in any way b Our invoice is unpaid c The defect is the result of misuse neglect improper installation environmental conditions non autho rized repair alteration or accident 7 No refund of t...