Installation

Operation

Turn the switch to the ON position.  The neon indicator in the switch should illuminate.  If the indicator fails 

to illuminate, recheck the connection, AC outlet and the fuse inside the power supply.

The PWS120 is cooled by convection and has no over temperature shutdown.  Ensure adequate ventilation 

for cooling.

The PWS240 is cooled by convection and forced air (via a fan).  The fan operates when the transformer tem-

perature exceeds 70 degrees Celsius.  If for some reason the temperature should exceed 100 degrees Celsius 

the unit will shut down.  After the unit has cooled down it will resume normal operation.

NOTE:

Place the unit in a well ventilated, open and cool area.  Do not block the openings of the fan intake at the 

bottom of the unit or the exhaust openings at the side of the unit!

This unit may be converted from 110Vac input operation to 220Vac input operation.  For 

instructions on this conversion please call Analytic Systems at 800-668-3884.

◆ 

MOUNTING

Mount the unit in a DRY location.  Allow at least 1 inch of clearance around the unit for adequate cooling.  

Do not block the ventilation slots on the sides of the unit.

  POWER CONNECTION

Ensure the switch is in the OFF position.  Connect the power cord to the power supply then connect the 

power cord to the AC source.  Connect the output of the power supply to the DC load.  The RED terminal is 

the positive output and the BLACK or WHITE terminal is the negative output.  

Содержание PWS120

Страница 1: ...Installation Operation Manual PWS120 PWS240 Power Supplies 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 1 800 668 3884 US CANADA www analyticsystems com...

Страница 2: ...2 Copyright 2005 2013 Analytic Systems Ware 1993 Ltd...

Страница 3: ...ord or plug provided If it will not fit the outlet have the proper cord installed by a qualified electrician Improper connection can result in a risk of an electric shock Your power supply should be g...

Страница 4: ...LTD 8128 River Way Delta B C V4G 1K5 Canada phone 604 946 9981 fax 604 946 9983 toll free 800 668 3884 US Canada email analyticinfo analyticsystems com web site www analyticsystems com Revised Mar 20...

Страница 5: ...eration NOTE Place the unit in a well ventilated open and cool area Do not block the openings of the fan intake at the bottom of the unit or the exhaust openings at the side of the unit This unit may...

Страница 6: ...chnical support Probable Cause Suggested Remedy Input voltage is low Check the input voltage The unit is in current limit due to a large reactive load or the output terminals are shorted together Chec...

Страница 7: ...he trans mit mode high current consumption The antenna being too close to the equipment may cause a slowly oscillating buzzing carrier heard in the receiver A loose coaxial connector or a broken or mi...

Страница 8: ...rchas ers name address and telephone number b Call Analytic Systems at 800 668 3884 or 604 946 9981 and request a return material authorization number RMA c Return the defective part or unit along wit...

Страница 9: ...tability fitness for the ordinary purposes for which such goods are used or fitness for a particular purpose or any other obligations on the part of the Warrantor or its employees and representatives...

Отзывы: