Analytic Systems IBI Series Скачать руководство пользователя страница 8

8

Ground Connection

The IBI uses a ground reference to operate its control circuitry which it reads through the Ground 

Connection. To set up this connection:

1.  Prepare an AWG18 wire with a #10 lug on one end. 
2.  Connect this end of the wire to

 Ground Point

3.  Connect the other end of the wire to the battery negative terminal or directly the engine block. If the 

ground is properly connected, the 

Grounding LED

 will be illuminated.  This is a very high efficiency 

LED that requires only 1 milli-amp from 12 volts so it will never discharge the battery.

Ignition (IGN) Connection

The Ignition (IGN) Connection is an optional connection done by the installer. If you read a normal 

charging current from your alternator to the battery banks after installing the IBI then you do not need 

to make this connection.
If there is no charging current after installing the IBI, you may need to make an Ignition Connection. 

Simply attach the original charging wire back to the alternator using a commonly available industrial 

axial leaded diode such as a 1N4001 with the cathode (bar end) facing the alternator. The diode will 

apply voltage from the battery to the alternator so it will start.

Содержание IBI Series

Страница 1: ...S IDEAL BATTERY ISOLATOR 101 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 Registered Company Battery Chargers Inve...

Страница 2: ...or open flames they could ignite the hydrogen gas produced by the battery leading to fire or explosion Connecting the battery leads is one of the most common causes of sparks 4 Always work in a well v...

Страница 3: ...s and infants anesthesia ventilators and infusion pumps as well as any other devices designated as critical by the U S FDA 8 Before working always make sure the unit is turned OFF Make sure any device...

Страница 4: ...Product Photo and Title Product Warnings and Advisories Table of Contents Introduction and Box Contents Main Parts Operation Options Specifications Warranty Revised October 26 2021 Copyright 2005 2021...

Страница 5: ...p found in diode based battery isolators At its maximum rated current the voltage drop is a miniscule 0 16V and essentially zero at low currents This way all the power of the alternator is applied to...

Страница 6: ...Positive Connections 5 16 18 Silicon Bronze Hex Bolt On the IBI2 model there are two connection bolts instead of the three pictured 3 Grounding LED 3mm LED Green Clear 4 Ground Point 10 32 Stainless...

Страница 7: ...nnection 1 Remove the existing wire from the alternator Cover the lug with electrical tape or shrink tubing and carefully move it aside Secure it with a tie wrap 2 Prepare a cable with a 5 16 ID lug o...

Страница 8: ...milli amp from 12 volts so it will never discharge the battery Ignition IGN Connection The Ignition IGN Connection is an optional connection done by the installer If you read a normal charging current...

Страница 9: ...0 in 2 5cm all around Weight 2 0 lb 0 9kg Material Marine Grade Aluminum Finish Black Blue or Red Anodize Epoxy Potting Connections Alternator 5 16 18 Silicon Bronze Hex Bolt Battery Positive 5 16 18...

Страница 10: ...10 Page intentionally left blank...

Страница 11: ...ing will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed...

Страница 12: ...GNED AND MANUFACTURED BY 800 668 3884 604 946 9983 sales analyticsystems com www AnalyticSystems com 101 8128 River Way Delta BC V4G 1K5 Canada Battery Chargers Inverters Power Supplies Voltage Conver...

Отзывы: