![Analytic Systems BCD605 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/analytic-systems/bcd605/bcd605_installation-and-operation-manual_2940510006.webp)
6
Designed and manufactured by: ANALYTIC SYSTEMS WARE (1993) LTD.
8128 River Way, Delta, B.C., V4G 1K5, Canada
phone (604) 946-9981 fax (604) 946-9983 toll free 800-668-3884 US/Canada
email: [email protected] web site: www.analyticsystems.com Revised May 2005
* Specifications subjects to change without notice.
* This is Analytic Systems’ suggested range. Please consult your battery manufacturer for their recommendations.
◆ The Actual charging rate depends upon the input/output voltage ratio. To obtain the charging capacity at any given input
voltage, use the following formula:
Charging Current = Input Volts/Output Volts x 40
For example, at 10.5VDC in and 13.6VDC out, the charging current = 10.5/13.6 x 40 = 30.8 amps
Specifications
Model
BCD605-12-12
BCD605-12-24
Input Volts (DC)
10.5 - 14
10.5 - 28
Input Amps (max)
50
Output Volts (DC)
13.6 ± 0.5 V
27.2 ± 0.5 V
Charging Amps
◆ 42
◆ 21
Output Crowbar
Output Volts x (1.3 ± 1%)
Input Fuses
AGC 30 x 2 Amp
Output Fuses
AGC 25 x 2 Amp
Low Input Voltage Alarm
10.5 VDC
Low Output Voltage Alarm
Output Voltage minus 2.5 VDC
Battey Banks
1
2 (Only if the input voltage < 15 Vdc)
Stages
2
Battery Size (Amp Hours)*
168 - 252
84 - 126
Transient Response
< 1V for 15A Surge
Efficiency
> 85 % @ maximum output
Temperature Range
-25 to +40 deg° C @ maximum output
Isolation
Any Input or Output to Case 500VDC
Input to Output Common Negative
Length
9.1 in / 23.1 cm
Width
7.8 in / 19.8 cm
Height
4.3 in / 10.8 cm
Clearance
1 Inch (2.5 cm) all around
Material
Marine Grade Aluminum
Finish
Black Powder Epoxy
Fastenings
18-8 Stainless
Weight
6.0 lb / 2.7 kg.