Analytic Systems BCD305 Series Скачать руководство пользователя страница 1

INSTALLATION & 

OPERATION MANUAL

BCD305 SERIES 
DC Battery Charger 

8128 River Way, Delta B.C. V4G 1K5  Canada  T. 604.946.9981  F. 604.946.9983  TF. 800.668.3884  (US/CANADA)

www.analyticsystems.com

An ISO9001 and AS9100 Registered Company 

Battery Chargers 

 Inverters 

 Power Supplies 

 Voltage Converters

Содержание BCD305 Series

Страница 1: ...S DC Battery Charger 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers I...

Страница 2: ...Copyright 2005 2016 Analytic Systems Ware 1993 Ltd Revised May 19 2016...

Страница 3: ...VICINITY OF A LEAD ACID BATTERY IS DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE SERVICING EQUIPMENT IN...

Страница 4: ...caps carefully follow manufacturer s recharging instructions 3 BATTERY CHARGER LOCATION i Never place battery charger directly above battery gases from battery will corrode and damage converter ii Nev...

Страница 5: ...indicators for low input voltage low output voltage and over temperature Safety features include reverse input protection over temperature shutdown current limiting short circuit protection with autom...

Страница 6: ...CD305 12 24 Input Volts DC 10 5 14 10 5 28 Input Amps max 30 30 Output Volts DC 13 6 0 5 V 27 2 0 5 V Charging Amps 26 13 Output Crowbar Output Volts x 1 3 1 Input Fuses AGC 20 x 2 Output Fuse AGC 30...

Страница 7: ...wires as follows Red to Positive Black to Negative POWER CONNECTION Two positive output terminals and two negative output terminals are provided Connect only one wire to each terminal Note that the c...

Страница 8: ...minals Operation Troubleshooting If the load exceeds the continuous rating for too long a period the internal temperature sensor will cause the unit to stop boosting the input voltage until the unit h...

Страница 9: ...it and move the jumper to the other position on J11 J11 is located next to the relay To change the position of the jumper first turn the unit off and disconnect the unit from both the power and batter...

Страница 10: ...otely as well as duplicating all the diagnostic indicators and audible alarm REMOTE CONNECTOR This connector is located on the side of the unit Important To prevent the possibility of High Voltage Ele...

Страница 11: ...ng will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed o...

Страница 12: ...Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage...