Analytic Systems BCD305-12-24 Скачать руководство пользователя страница 6

6

Installation

MOUNTING

Mount the unit in a DRY location. Allow at least 1 inch of clearance for adequate cooling.

POWER CONNECTION

The unit is supplied with input power leads 1 meter long. This should normally be adequate to 

connect to a source of power. If you must extend the cable:

• Use the smallest extension length possible.

• Use no less than 10 gauge conductors.

• Splice and solder the joints.

• Protect the joints with heat shrink tubing.

Connect the wires as follows:

• Red to Positive

• Black to Negative

POWER CONNECTION

Two positive output terminals and two negative output terminals are provided. Connect only 

one wire to each terminal.

Note that the current specifications are for input current. To obtain the maximum output 

current capability at any given input voltage, use the following formula:

Output Current = Input Volts / Output Volts x 26

For example:

10 VDC in and 27 VDC out, the max output current = 10/27 x 26 = 9.6 Amps.

20 VDC in and 27 VDC out, the max output current = 20/27 x 26 = 19.3 Amps

It is recommended to parallel the output connections if the unit is used as a single bank battery charger.

Содержание BCD305-12-24

Страница 1: ...SERIES DC Battery Charger 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 Registered Company Battery Chargers Inverte...

Страница 2: ...ctly above battery gases from battery will corrode and damage battery charger 6 Never allow battery acid to drip on to the battery charger 1 WARNING RISK OF EXPLOSIVE GASES i WORKING IN VICINITY OF A...

Страница 3: ...diately with soap and water If acid enters eye immediately flood eye with running cold water for at least 10 v NEVER smoke or allow a spark or flame in the vicinity of a battery vi Be extra cautious t...

Страница 4: ...OF CONTENTS Front Cover Product Photo and Title Product warnings and advisories Table of Contents Description Overview of product Box Contents Operation instructions Mounting Instructions Connection...

Страница 5: ...ure shutdown current limiting short circuit protection with automatic recovery input undervoltage shutdown reverse battery protection and output overvoltage crowbar Optional features include a dry con...

Страница 6: ...wires as follows Red to Positive Black to Negative POWER CONNECTION Two positive output terminals and two negative output terminals are provided Connect only one wire to each terminal Note that the c...

Страница 7: ...minals Operation Troubleshooting If the load exceeds the continuous rating for too long a period the internal temperature sensor will cause the unit to stop boosting the input voltage until the unit h...

Страница 8: ...1 It will be next to the relay as is shown in the above diagram Simply move the jumper to the desired position as is shown in the above diagram Replace the cover and re install the four screws Reconne...

Страница 9: ...Model BCD305 12 24 Input Volts DC 10 5 24 Input Amps max 30 Output Volts DC 27 2 0 5 V Charging Amps 13 Output Crowbar Output Volts x 1 3 1 Input Fuses AGC 20 x 2 Output Fuse AGC 30 x 2 Low Input Volt...

Страница 10: ...rt for each unit Available as Add on to M Option J MIL810G in house tested and report for each unit Available as Add on to M Option K Synchronized Inverters L not assigned M Military Rugged Package MI...

Страница 11: ...ng will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed o...

Страница 12: ...River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 Registered Company Battery Chargers Inverters Power Supplies Voltage Conve...

Отзывы: