Analytic Systems BCA1000V Скачать руководство пользователя страница 15

15

Limited Warranty

1.  The equipment manufactured by Analytic Systems Ware (1993) Ltd. (the “Warrantor”) is warranted to be free 

from defects in workmanship and materials under normal use and service.

2.  This warranty is in effect for:

a.  3 Years from date of purchase by the end user for standard products offered in our catalog.
b.  2 Years from date of manufacture for non-standard or OEM products
c.  1 Year from date of manufacture for encapsulated products.

3.  Analytic Systems will determine eligibility for warranty from the date of purchase shown on the warranty card 

when returned within 30 days, or

a.  The date of shipment by Analytic Systems, or
b.  The date of manufacture coded in the serial number, or 
c.  From a copy of the original purchase receipt showing the date of purchase by the user.

4.  In case any part of the equipment proves to be defective, the Purchaser should do the following:

a.  Prepare a written statement of the nature of the defect to the best of the Purchasers knowledge, and 

include the date of purchase, the place of purchase, and the Purchasers name, address and telephone 

number.

b.  Call Analytic Systems at 800-668-3884 or 604-946-9981 and request a return material authorization 

number (RMA).

c.  Return the defective part or unit along with the statement at the Purchasers expense to the Warrantor; 

Analytic Systems Ware (1993) Ltd., 8128 River Way, Delta, B.C., V4G 1K5, Canada.

5.  If upon the Warrantor’s examination the defect proves to be the result of defective material or workmanship, 

the equipment will be repaired or replaced at the Warrantor’s option without charge, and returned to the 

Purchaser at the Warrantor’s expense by the most economical means. Requests for a different method of return 

or special handling will incur additional charges and are the responsibility of the Purchaser.

6.  Analytic Systems reserves the right to void the warranty if:

a.  Labels, identification marks or serial numbers are removed or altered in any way.
b.  Our invoice is unpaid.
c.  The defect is the result of misuse, neglect, improper installation, environmental conditions,  non-autho-

rized repair, alteration or accident.

7.  No refund of the purchase price will be granted to the Purchaser, unless the Warrantor is unable to remedy the 

defect after having a reasonable number of opportunities to do so.

8.  Only the Warrantor shall perform warranty service. Any attempt to remedy the defect by anyone else shall 

render this warranty void.

9.  There shall be no warranty for defects or damages caused by faulty installation or hook-up, abuse or misuse of 

the equipment including exposure to excessive heat, salt or fresh water spray, or water immersion except for 

equipment specifically stated to be waterproof.

10. No other express warranty is hereby given and there are no warranties that extend beyond those described 

herein. This warranty is expressly in lieu of any other expressed or implied warranties, including any implied 

warranty of merchantability, fitness for the ordinary purposes for which such goods are used, or fitness for a 

particular purpose, or any other obligations on the part of the Warrantor or its employees and representatives.

11. There shall be no responsibility or liability whatsoever on the part of the Warrantor or its employees and rep-

resentatives for injury to any person or persons, or damage to property, or loss of income or profit, or any other 

consequential or resulting damage which may be claimed to have been incurred through the use or sale of the 

equipment, including any possible failure of malfunction of the equipment, or part thereof.

12. The Warrantor assumes no liability for incidental or consequential damages of any kind

Содержание BCA1000V

Страница 1: ...INSTALLATION OPERATION MANUAL BCA1000V AC Source Battery Charger An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage Converters...

Страница 2: ...Copyright 2005 2016 Analytic Systems Ware 1993 Ltd Revised May 18 2016...

Страница 3: ...power switch to the off position ALL BATTERY CHARGERS 1 WARNING RISK OF EXPLOSIVE GASES i WORKING IN VICINITY OF A LEAD ACID BATTERY IS DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTE...

Страница 4: ...ot overfill For a battery without cell caps carefully follow manufacturer s recharging instructions GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS The plug must be plugged into an outlet that is...

Страница 5: ...ly the charger will supply the DC load as well as charge float the battery In case the AC power fails or if the charger stops working the battery will automatically power the DC load As soon as the AC...

Страница 6: ...n Coefficient 30mV o C 60mV o C 80mV o C 120mV o C General Stages 2 or 3 Noise on Input 50 milli volts Noise on Output 50 milli volts Transient Resp 2V for 10A Surge Efficiency 75 maximum output Temp...

Страница 7: ...9 amps is the maximum current draw so a 10 amp circuit breaker should be used in the circuit panel to feed power to the BCA1000 OUTPUT CONNECTIONS Two Positive output terminals and two Negative output...

Страница 8: ...a period of time which may be minutes to hours the batteries will reach the float voltage at which time the charging light will go off and the charging current will reduce as necessary to maintain the...

Страница 9: ...ant current until the battery voltage reaches a slightly elevated level The battery is maintained at this voltage while the charging current diminishes to a low value and then the battery is switched...

Страница 10: ...nit will turn off the outputs After the unit cools sufficiently it will automatically come back on If this happens frequently remount the unit for increased airflow so it cools better CHARGING Indicat...

Страница 11: ...the unit If no sensor is used the charger will default to standard output voltage For installation instructions of the temperature sensor please see the section entitled Remote Battery Temperature Se...

Страница 12: ...iately The charger will charge the battery at approximately 10 of its normal rate i e 4 amps for a 40 amp charger until the battery reaches equalize voltage and then the current reduces as necessary t...

Страница 13: ...the battery The sensor may be placed on top of the battery but it should be secured to the battery so as to prevent it from losing contact with the battery Battery Charger Temperature Compensation The...

Страница 14: ...14 Page intentionally left blank...

Страница 15: ...ng will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed o...

Страница 16: ...An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage Converters...

Отзывы: