UG-1134
EVAL-ADAU1467Z
Rev. A (Draft) | Page 4 of 55
SETTING UP THE EVALUATION BOARD
Using the EVAL-ADAU1467Z evaluation board requires a PC
running Windows® XP or later with a USB interface and an
internet connection. The PC communicates with the evaluation
board using the included USBi interface. The software tool chain
used with the
, a fully graphical user
interface (GUI)-based programming environment. No DSP
programming is required. A full version of
, which
includes a library of DSP building blocks and the required USBi
drivers, is available for download from the
software page on the Analog Devices website at
SOFTWARE
To download the latest version of
, take the
following steps:
1.
Go to the
software page on the Analog
Devices website, and select the latest version of the
software from the
Downloads and Related
Software
section.
2.
Determine whether the software must be installed on a
32-bit or 64-bit version of Windows, and locate the latest
release version of
as appropriate.
3.
Download the installer and execute the executable.
Follow the prompts, and accept the license agreement to
install the software.
The drivers for the USBi are installed automatically by the
SigmaStudio installer. This may be confirmed by taking the
following steps:
1.
Using the included cable, connect the USBi to the
computer.
2.
Check that both the yellow I
2
C LED and the red power
indicator LED are illuminated (see Figure 3).
3.
In the Windows
Device Manager
, under the
Universal
Serial Bus controllers
section, check that
Analog Devices
USBi (programmed)
is displayed (see Figure 2).
Figure 2. Confirming Driver Installation Using the Device Manager
Figure 3. State of the USBi Status LEDs After Driver Installation
DISABLING THE SELF BOOT SWITCH
When setting up the EVAL-ADAU1467Z evaluation board,
ensure that the SELFBOOT switch is in the off position.
SELFBOOT is the first switch of the four position, dual inline
package (DIP) switches, S3. The off position is toward the
bottom of the board, away from the silkscreen label, SELFBOOT.
The default position of this switch is the off (disabled) position,
which prevents the
operation at power-up. When the switch is in the on position, the
LED D3 is illuminated, and a self boot operation is executed,
causing the
to attempt to load code from the
EEPROM (U10) when it powers up or comes out of reset.
Содержание SigmaDSP ADAU1463
Страница 44: ...UG 1134 EVAL ADAU1467Z Rev A Draft Page 44 of 55 Figure 110 EVAL ADAU1467ZLayout Top Copper D R A F T...
Страница 45: ...EVAL ADAU1467Z UG 1134 Rev A Draft Page 45 of 55 Figure 111 EVAL ADAU1467Z Layout Layer 2 Ground D R A F T...
Страница 47: ...EVAL ADAU1467Z UG 1134 Rev A Draft Page 47 of 55 Figure 113 EVAL ADAU1467Z Layout Layer 4 Power D R A F T...
Страница 48: ...UG 1134 EVAL ADAU1467Z Rev A Draft Page 48 of 55 Figure 114 EVAL ADAU1467Z Layout Layer 5 Ground D R A F T...
Страница 49: ...EVAL ADAU1467Z UG 1134 Rev A Draft Page 49 of 55 Figure 115 EVAL ADAU1467Z Layout Bottom Copper D R A F T...