QUICK START PROCEDURE 

Demonstration circuit SCP-LT3483-EVALZ is easy to set 
up to evaluate the performance of any SCP hardware 
configuration. Refer to Figure 2 and follow these steps:  

1. The  SCP-LT3483-EVALZ  ships  with  a  default  output 

voltage  of  –15V.  To  change  the  output  voltage,  see 
“Configuration Settings” section, and modify the board 
accordingly. Be sure to check for open connections or 
solder shorts after making any modifications. 

2. Connect  the  SCP-INPUT-EVALZ  and  SCP-OUTPUT-

EVALZ boards to the SCP-LT3483-EVALZ board (refer 
to Figure 2) and connect the input board to a voltage 
source, V

SOURCE

. Connect the output board to a volt-

meter or dynamic load. Slowly raise the input voltage 
until the SCP-LT3483-EVALZ into regulation and sweep 
V

SOURCE

 through the desired range of operation. 

  NOTE: Make sure that the input voltage is always within 

specification. If using a dynamic load to measure out-
put voltage, make sure the load is initially set to zero. 

3. Check for proper output voltage. The output should be 

regulated at the programmed value (±5%). 

4. Once  the  proper  output  voltage  is  established,  power 

off V

SOURCE 

and similarly test other boards in the SCP 

system until all elements have been individually verified 
prior to assembling into the final circuit configuration. 

  NOTE: When measuring the input or output voltage rip-

ple, use the optional SMA connector locations available 
on the input, output, 1 

´

 5, 1 

´

 2, and 5 

´

 1 breakout 

boards.  Avoid  using  the  test  point  connections  with 
long scope leads. 

 

Figure 2.

 

Proper Measurement Equipment Setup (Use SMA connectors for Measuring Input or Output Ripple) 