EVALUATION SOFTWARE EXAMPLE OPERATION
These examples assume that the setup described in the Setting
Up the Evaluation Board section is used.
WHEN
ADUM4138
IS NOT COMMUNICATING
If the
ADuM4138
is not powered, and the
USB-SDP-CABLEZ
is plugged into the evaluation board, read commands usually
report all 0s. By reading all registers, it is possible to see if the
ADuM4138
is communicating properly, as the address bits are
displayed on a read command. Additionally, with default
settings, the Flyback_V setting is 111 (see Figure 9).
EXAMPLE READ COMMANDS
To perform a read command, first power up the
ADuM4138
.
Then click the read button of the desired address to be read.
If the
ADuM4138
EEPROM has never been programmed, it is
expected that all 0s except the address are returned, and a
Flyback_V setting of 111 in default configuration. Figure 10
shows
Read Addr:00
,
Read Addr:01
, and
Read Addr:10
clicked on a new
ADuM4138
.
162
45-
0
0
9
Figure 9. All Zeros Show Communication is Not Occurring