UG-900
EVAL-ADN4651EB1Z/EVAL-ADN4652EB1Z User Guide
Rev. A | Page 4 of 13
EVALUATION BOARD CONFIGURATION
SETTING UP THE EVALUATION BOARD
, power
supplies are configured using Jumpers P4 and P7 (see Table 1)
and connected to the J9 and J10 SMA connectors (see Table 2 and
Table 3). A 3.3 V power supply can be applied to Side 1 and/or
Side 2 of the
by removing Jumpers P4
(Side 1) and P7 (Side 2). If a 2.5 V supply is connected to the
board, the relevant jumper must be inserted (P4 for Side 1 and
P7 for Side 2). At 300 MHz with a load resistance of 100 Ω, the
maximum operating current from each power supply is 90 mA.
When using a 3.3 V power supply, V
IN1
and V
DD1
(Pin 1 and Pin 3
) are bypassed to GND
1
using 1 µF
capacitors. V
IN2
and V
DD2
) are bypassed to GND
2
using 1 µF capacitors. When
using a 2.5 V power supply, V
IN1
or V
IN2
is connected directly to
V
DD1
or V
DD2
by shorting Jumpers P4 or P7, respectively. Both
V
DD1
pins are also bypassed to GND
1
with 0.1 µF capacitors. Both
V
DD2
pins are also bypassed to GND
2
with 0.1 µF capacitors.
An example operation of the
is shown in
Figure 5 (signal generator and oscilloscope connections are
reversed for
SMA connectors expose all LVDS inputs and outputs for the
, but are reversed for the
(see Table 2 and Table 3). Connect a signal
generator to the board using the J1 and J2 connectors and set up
a 300 MHz square wave clock with an amplitude of 350 mV and
an offset of 1.2 V. Connect the oscilloscope directly to the J5
and J6 connectors to perform timing measurements including
propagation delay and skew. Precision measurements, for
example, jitter, using a differential probe requires attaching the
probe at the R7 or R3 resistors and potentially cutting the traces
to the connectors to minimize reflections.
A plot of the oscilloscope connected via the J5 and J6 connectors is
shown in Figure 3. Channel 3 (green) and Channel 4 (purple)
show the J5 and J6 connectors separately (single-ended) with
the differential signal (orange).
Operation of the second isolated LVDS channel is shown in
Figure 4. In contrast to Figure 5, the oscilloscope now connects
via the J3 and J4 connectors and the signal generator connects to
the J7 and J8 connectors. Channel 3 (green) and Channel 4
(purple) show the J3 and J4 connectors separately (single-ended)
with the differential signal (orange).
13761-
002
Figure 3. D
OUT1−
and D
OUT1+
with a 300 MHz Clock, Single-Ended and Differential
13761-
003
Figure 4. D
OUT2−
and D
OUT2+
with a 300 MHz Clock, Single-Ended and Differential