UG-1492
Rev. 0 | Page 7 of 22
17
332
-00
6
Figure 6.
Attached Hardware
Section with Connected EVAL-AD5753SDZ
7.
Double-click
EVAL-AD5753SDZ
to open the
block
diagram (see Figure 7). The
INITIAL CONFIGURATION
menu appears on the left side of the window. Several
register settings can be configured under this menu, and
are written to the device in the appropriate order. The
DIG_DIAG_STATUS
,
RESET_OCCURED
, and
CAL_MEM_UNREFRESHEDLED
indicators are
highlighted red. Write the initial configuration values to
clear the error flags. If the device is power cycled, or if the
USB cable is disconnected and reconnected while the
software is open, contact with the EVAL-AD5753SDZ is
lost. If contact is lost, click the
System
tab, click the USB
symbol on the EVAL-AD5753SDZ, and then click
Acquire
to restore communication with the EVAL-AD5753SDZ.
17
332
-00
7