DEMO MANUAL DC2569A

QUICK START PROCEDURE

Figure 2. Measuring Input or Output Ripple

Figure 1. Proper Measurement Equipment Setup

+ –

+ –

+

+

+

+

LOAD

I

OUT

I

IN

V

OUT

V

IN

LAB

SUPPLY

DC2569A

+

V

OUT

GND

C

OUT

Demonstration circuit DC2569 is easy to set up to evaluate 

the performance of the LTM4661. For proper measure-

ment equipment setup refer to Figure 1 and follow the 

procedure below: 
NOTE: When measuring the input or output voltage ripple, 

care must be taken to minimize the length of oscilloscope 

probe ground lead. Measure the input or output voltage 

ripple by connecting the probe tip directly across the V

IN

or V

OUT

 and GND terminals as shown in Figure 2.

1. With power off, connect the input power supply to V

IN

and GND.

2. Keep the load set to 0A or disconnected.

3. Turn the input power source on and slowly increase the 

input voltage. Be careful not to exceed 5.5V. 

  NOTE: Make sure that the input voltage V

IN

 does not 

exceed 5.5V. 

4. Set the input voltage to 5V and check for the proper 

output voltage of 12V. If there is no output, temporarily 

disconnect the load to make sure that the load is not 

set too high.

5. Once the proper output voltage is established, adjust 

the load and observe the output voltage regulation, 

ripple voltage, efficiency and other parameters. 