Installing the ADXRS450 Software Evaluation GUI 

The software GUI installation has been created to include any 
required National Instruments drivers and run-time engines 
which are necessary for proper operation.  In order to run the 
software GUI installation routine, double click on the 
“setup.exe” file located in the /

ADXRS450 Evaluation 

Software

/ folder on the included CD.  The user will be greeted 

with the following screen: 

 

Figure 11: ADXRS450 evaluation software installation welcome screen 

From this point, the following steps should be completed in 
order to successfully install the evaluation software. 
1.

 

Select the destination directory

.  The installer will auto-

populate the directory names where it would like to store 
the software GUI and required National Instruments 
products (Figure 6).  These directories can be changed by 
the user, if desired, however most installations can proceed 
with the default values.  Click Next. 

2.

 

License Agreement

.  Once the installation directories have 

been chosen, the user will be prompted with the National 
Instruments Software License Agreement.  It is highly 
recommended that the user read this agreement before 
accepting, and clicking the Next button. 

3.

 

Start Installation

.  The installer will then list the required 

components which need to be installed on the user’s PC 
(Figure 7).  Click Next. 

4.

 

Installation Complete

.  The installer will now complete 

the installation of the software evaluation GUI and all 
required National Instruments drivers and run-time 
engines.  After the installation is complete, the user will see 
the screen shown in Figure 8.  Click Finish to complete the 
installation. 

 
 
 
 

 

Figure 12: Destination Directory Selection 

 

Figure 13: Start Installation screen (Note: depending on the requirements of 

each PC, the components listed above may be different) 

 

Figure 14: Installation Complete! 

Содержание ADXRS450

Страница 1: ...hamber for temperature or humidity testing Separating the boards mitigates corruption of data due to the temperature and humidity effects of other components The ISEB is a universal main board and is...

Страница 2: ...ion 4 Updating Repairing the ISEB Firmware 5 Inertial Sensor Evaluation System Graphical User Interface 8 Getting Started 8 View and Record Data 9 Temperature Test 10 Noise and Root Allan Variance 11...

Страница 3: ...leted the user can now connect the ISEB main board to the computer via the included USB cable Once connected if the previously installed drivers are not automatically associated with the device then t...

Страница 4: ...e Manager a Windows Vista may request that the user allow access to this panel and Administrative privileges may be required b The window shown in XYZ should now open 3 Expand the Ports COM LTP menu i...

Страница 5: ...COM port is selected click OK to accept the changes and go back to the main screen Figure 9 Selecting the Correct COM Port for the Downloader When the ISEB is connected the correct firmware is selecte...

Страница 6: ...s Figure 6 These directories can be changed by the user if desired however most installations can proceed with the default values Click Next 2 License Agreement Once the installation directories have...

Страница 7: ...o generate the device s required high voltage supply For more information on using alternate high voltage supplies refer to the ADXRS450 datasheet as well as the Alternate External High Voltage Supply...

Страница 8: ...OM port Refer to the PC s Device Manager under the Ports COM LTP submenu in order to determine which COM port has been assigned to the ADI Inertial Sensor Evaluation System Select this COM port from t...

Страница 9: ...software packages However the record functionality can be performed indefinitely if desired by the user Secondary information which is transmitted along with the plotted signals is graphically repres...

Страница 10: ...ew and Record panel allowed Data is again streamed to a file to allow for an indefinite length for data recording Before recording the data on this panel if the user wishes to adjust for any null offs...

Страница 11: ...t be run at least overnight during which time care should be taken to ensure that the device is in a temperature stable and disturbance free environment Any rotational rate input into the gyroscope ca...

Страница 12: ...intended application voltage To record the data from this panel ensure that the Record Bias Run Data box is checked before clicking the View Turn on Bias Stability button The user will be prompted to...

Страница 13: ...timings such that this specification is observed then it can be useful to know the behavior of the device from the moment power is applied By sending a series of Sensor Data Requests immediately after...

Страница 14: ...by the evaluation GUI The software must perform an initial calibration step in order to accurately calculate the angle of rotation 3 Once the null calibration is performed slowly rotate the satellite...

Страница 15: ...d with the high voltage supply the proper current is sourced to the ADXRS450 The supply requirements are described in detail in the ADXRS450 datasheet In short the main requirement for the external hi...

Страница 16: ...7 HEADER PINOUT Figure 26 ISEB 20 Pin Header Pinout ESD CAUTION 1 S1 2 3 S2 4 5 S3 6 7 S4 8 CS2 9 VS2 10 VS1 11 12 ST1 13 ST2 14 SCL1 15 SDA1 16 CLK 17 MOSI 18 MISO 19 CS3 20 CS4 P1 3 3V CS2 VS2 VS1 S...

Страница 17: ...or use of evaluation boards Information furnished by Analog Devices is believed to be accurate and reliable However no responsibility is assumed by Analog Devices for its use nor for any infringements...

Отзывы: