background image

UG-1071 

ADuCM362/ADuCM363 Getting Started Guide

 

Rev. 0 | Page 4 of 6 

IAR EMBEDDED WORKBENCH 

The IAR Embedded Workbench integrates all the tools 
necessary to edit, assemble, and debug code. The fastest way to 
get started is to open an existing workspace by following these 
steps: 

 

1.

 

Open the IAR tools from the 

Start Menu

2.

 

Within the IAR IDE, click 

File

 > 

Open

 > 

Workspace

 and 

open a workspace provided by Analog Devices (for example, 

C:\ADuCM36x…\code\ADuCM362\examples\Blink\DI
O.eww

). 

3.

 

Compile and download the code to the device using 

Project

 > 

Rebuild

 

All

 and then 

Project

 > 

Download 

Active Application

4.

 

Click 

No

 if a pop-up window appears identifying an 

unknown device. 

5.

 

  To run the code, press RESET on the evaluation board or 
enter debug mode by clicking the 

Download and Debug

 

button (see Figure 6) and then click 

Go

 (see Figure 7).  

15

16

9-

0

07

 

Figure 6. 

Download and Debug

 Button 

15

16

9-

0

08

 

Figure 7. 

Go

 Button 

6.

 

When running, the red LED marked DISPLAY on the 
evaluation board flashes. 

ELVES.EXE 

Elves.exe is an application that chooses functions from the 
provided function sets and function parameters. Elves.exe can 
be integrated into the Keil μVision5 and IAR tools under the 
tool menus. For instructions, run 

Elves.exe

 (for example, at 

C:\ADuCM36x…\Software Tools\Elves\Elves.exe

) and press the 

F1 key or click the 

Help

 button.  

EVALUATION BOARD SETUP PROCEDURES 

Assembling and Connecting the Hardware 

Do not plug in the USB cable before the software is installed. 
Use the following steps to connect the hardware: 

1.

 

Insert the USB cable provided between the PC and the J-Link 
OB emulator (emulator shown in Figure 8)

2.

 

The red LED (LED1) flashes until initialization of the drivers 
completes. 

3.

 

Details for installation of the drivers appear on the screen 
the first time the user plugs the evaluation board into the 
PC or if using a different USB port. Allow the installation 
of these drivers to complete as they provide a virtual 
communication port on the PC that allows the evaluation 
board to appear as a virtual serial communication port to the 
UART port of th

ADuCM362

/

ADuCM363

 device. 

4.

 

If using the virtual serial communication port to the UART, 
ensure Jumpers LK3 and LK5 are in place on the evaluation 
board (see Figure 9)

5.

 

Plug the 10-pin DIL connector of the J-Link OB emulator 
into th

EVAL-ADuCM362QSPZ

 or 

EVAL-

ADuCM363QSPZ

 

6.

 

The evaluation board is powered by computer from the the 
USB cable connected to the J-Link OB emulator. The green 
POWER LED turns on. 

13

96

7-

0

04

 

Figure 8. Emulator, Top View 

1396

7-

00

5

 

Figure 9. J-Link OB Connection Details 

 

Отзывы: