![Analog Devices ADMV4530IF-EVALZ Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/analog-devices/admv4530if-evalz/admv4530if-evalz_user-manual_2939902007.webp)
UG-1759
Rev. A | Page 7 of 21
PLUG-IN DETAILS
user interface with labels is shown
in Figure 9. The labels correspond to items listed in Table 1,
which describes the functionality of each block. For additional
detailed programming, refer to the
data sheet.
231
54-
009
Block Diagram with Labels
Block Diagram Label Functions (See Figure 9)
Label Function
A
Use the
Initial Configuration
to initialize the ADMV4530IQ-EVALZ or the ADMV4530IQ-EVALZ evaluation board. Set the
following under the
Initial Settings
section:
Mixer Mode Selection:
select IF, I/Q, or user defined mode.
Requested LO Frequency:
enter the requested local oscillator (LO) frequency.
Reference Frequency Input:
enter the reference input frequency.
Reference Doubler:
use the dropdown menu to disable or enable the reference doubler.
R Word:
enter the R word value.
Reference Divide-by-2:
use the dropdown menu to disable or enable the reference divide by 2.
CP Current:
use the dropdown menu to select the charge pump (CP) current.
Summary:
click this button to review the settings for the initial setup.
Apply
: click this button to apply the initial settings. The settings are reflected in the right sections. Note that clicking
Apply
Changes
(Label K1) does not update the changes in this section.