UG-1283
User Guide
Rev. A | Page 18 of 24
MISC TAB
In the
MISC
tab, configuration of miscellaneous functions is
available (see Figure 34).
Two sets of registers are on the
device to control
the LNA and PA bias outputs and to set the DACs when the
corresponding bias outputs are in the on and off states. The register
values can be entered in the
Bias ON
and
Bias OFF
sections.
Each set of register values is transferred to the ADAR1000-
EVALZ when the respective
Write Bias Values
buttons are clicked.
Under the
Enables
section, if the
BIAS CTRL
check box is
cleared, the bias digital-to-analog converter (DAC) outputs use
the
Bias ON
register values only.
If the
BIAS CTRL
check box is selected while the device is in
receive mode, the PA DACs use the
Bias OFF
register values,
and the LNA DAC uses the
Bias ON
register value. If the check
box is selected while the device is in transmit mode, the
opposite is true, and the PA DACs use the
Bias ON
register
values, and the LNA DAC uses the
Bias OFF
register values.
In the
ADC
section, use the
MUX SEL
dropdown menu to
choose the temperature sensor or the power detector, one
through four, for analog to digital conversion.
Select
ADC EN
,
CLK EN
, and
ST CONV
and then click
Write
ADC Values
to initiate analog to digital conversion.
Click
Read ADC Word
to access the conversion result.
The
Memory Control
section allows setting or clearing the
corresponding bits in Register 0x038 for various memory
control functions.
1
678
8-
0
12
Figure 34.
MISC