UG-1024
AD8209A-EVALZ User Guide
Rev. 0 | Page 4 of 8
POWER-UP PROCEDURE
After completing the initial configuration, use the following
procedure to power up the board:
1.
Set the power supply to 5.0 V.
2.
Turn on the power supply. The typical supply current of
is 1.6 mA. Current drawn from the power
supply must not exceed 3 mA.
3.
Configure the signal source to output a 1 kHz sine wave,
200 mV p-p with a 100 mV offset voltage. If the signal source
is relative to a 50 Ω impedance, set the amplitude to
100 mV p-p.
4.
Enable the signal source. The oscilloscope must be able to
measure 2.8 V p-p sine wave at the output of the
14790-
006
Figure 6. Final Result of the Quick Start Procedure with a 2.8 V p-p Signal
Appearing on the Oscilloscope Using an
Board