AD5100
Rev. A | Page 4 of 36
SPECIFICATIONS
ELECTRICAL SPECIFICATIONS
6 V ≤ V
1MON
≤ 30 V and 3 V ≤ V
2MON
≤ 30 V, −40°C ≤ T
A
≤ +125°C, unless otherwise noted.
Table 2.
Parameter Symbol
Conditions
Typ
Unit
HIGH VOLTAGE MONITORING INPUTS
V
1MON
Voltage Range
V
1MON
6
30 V
Input Resistance
R
IN_V1MON
36 55
70 kΩ
OV, UV Threshold Tolerance
ΔOV, ΔUV
T
A
= 25°C
−1.6
+1.6
%
T
A
= −40°C to +85°C
−1.8
+1.8
%
T
A
= −40°C to +125°C
−2
+2
%
Hysteresis
1.5
%
Programmable Shutdown Hold Time
Tolerance (See Figure 7 and Table 8)
Δt
1SD_HOLD
T
A
= 25°C; does not apply to
Code 0x7
−10 +10 %
Programmable Shutdown Delay Tolerance
Δt
1SD_DELAY
T
A
= 25°C; does not apply to
Code 0x7
−10 +10 %
T
A
= −40°C to +125°C; does not
apply to Code 0x7
−17 +17 %
Fault Detection Delay
t
FD_DELAY
60
μs
Glitch Immune Time
t
GLITCH
Guaranteed by evaluation
45
μs
V
2MON
Input Voltage
V
2MON
Minimum voltage on V
2MON
to
ensure AD5100 V
REG
power-up
2.2
V
Voltage Range
V
2MON
3
30 V
Input Resistance
R
IN_V2MON
500 675
860 kΩ
On, Off Threshold Tolerance
ΔOn, ΔOff
T
A
= 25°C
−2
+2
%
T
A
= −40°C to +85°C
−2.4
+2.4
%
T
A
= −40°C to +125°C
−2.5
+2.5
%
Hysteresis
1.5
%
Turn-On Programmable SHDN Hold Time
Tolerance (See
and
)
Δt
2SD_HOLD
T
A
= 25°C; does not apply to
Code 0x7
−10 +10 %
Turn-Off Programmable SHDN Delay Time
Tolerance (See
Δt
2SD_DELAY
T
A
= 25°C; does not apply to
Code 0x07
−10 +10 %
T
A
= −40°C to +125°C; does not
apply to Code 0x7
−17 +17 %
Fault Detection Delay
t
FD_DELAY
V
2MON_OFF
only
60
μs
Glitch Immune Time
t
GLITCH
45
μs
SHDN
SHDN Output High
V
OH
V
RAIL
= V
REG
, I
SOURCE
= 40 μA
2.4
V
V
RAIL
= V
1MON
, I
SOURCE
= 600 μA
V
1MON
− 0.5
V
SHDN Output Low
V
OL
I
SINK
= 1.6 mA
0.4
V
V
1MON
= 12 V, I
SINK
= 40 mA
1.5
3
V
SHDN Sink Current
I
SINK
V
1MON
= 12 V, SHDN forced to 12 V
10
13.5
mA
SHDNWARN (Open-Drain Output)
SHDNWARN Inactive Leakage Current
I
OH_SHDNWARN
0.9
μA
SHDNWARN Active
V
OL_SHDNWARN
I
SINK
= 3 mA
0.4
V