Anaheim Automation MBC25081-06 Скачать руководство пользователя страница 6

June 2019

L011804

Connecting to the MBC15081

The MBC25081 is designed with cost savings and size as two of the primary design criteria.  For this reason, 
the MTA-100 series connector was chosen for these products as a reliable small and low cost connector.  
This is a common Insulation Displacement Connector (IDC) manufactured by AMP Corporation.  The 
inputs to the driver are on a 7-pin connector and the motors are on a 4-pin connector.  These connectors 
are not supplied with the driver, but can be purchased from Anaheim Automation or AMP/Tyco Electronics.  

These two images show how a hand tool can be used to quickly make the cable to connect to the driver.  
This cable can be made in approximately 10 seconds per wire using the hand tool.

Tooling from  AMP/Tyco Electronics

Part Number 

Description

58074-1

Manual Hand Tool with Interchangeable Head (shown above)

58075-1

Air Hand Tool with Interchangeable Head 

58338-1

Air Bench Mount Tool with Interchangeable Head and Foot Switch

58246-1

Die Head for Closed End MTA-100 Connectors (shown above)

Connectors from AMP/Tyco Electronics

Part Number 

Description

640440-7

7 Pin MTA-100 Connector, Closed End with Lock, 22 AWG Red, Tin Plated

640440-4

4 Pin MTA-100 Connector, Closed End with Lock, 22 AWG Red, Tin Plated

640441-7

7 Pin MTA-100 Connector, Closed End with Lock, 24 AWG White, Tin Plate

640441-4

4 Pin MTA-100 Connector, Closed End with Lock, 24 AWG White, Tin Plated

640440-7

7 Pin MTA-100 Connector, Closed End with Lock, 26 AWG Blue, Tin Plated

640442-4

4 Pin MTA-100 Connector, Closed End with Lock, 26 AWG Blue, Tin Plated

July 2018

Содержание MBC25081-06

Страница 1: ...081 06 Bipolar Microstep Driver User s Guide 4985 E Landon Drive Anaheim CA 92807 e mail info anaheimautomation com 714 992 6990 fax 714 992 0471 website www anaheimautomation com A N A H E I M A U T...

Страница 2: ...being received yellow LED The MBC25081 06 is a compact low profile package meant to be used where space is limited but performance is expected MBC25081 06 Features 2 5 Amps Phase Output Current 40 C...

Страница 3: ...ce Current Mode On Off Active Off Inactive open On Notes Opens Inputs are inactive and internally pulled up to 5VDC for JP1 position 1 2 Sinking Open Inputs are inactive and internally pulled down to...

Страница 4: ...se 3 of the step motor are connected to pins 1 and 2 on connector P2 Phase 2 and Phase 4 of the step motor are connected to pins 3 and 4 on connector P2 Please refer to the figure for a typical APPLIC...

Страница 5: ...s Half Coil Connection When configuring a 6 lead motor in half coil connected from one end of the coil to the center tap multiply the specified per Phase or unipolar current rating by 1 4 to determine...

Страница 6: ...imately 10 seconds per wire using the hand tool Tooling from AMP Tyco Electronics Part Number Description 58074 1 Manual Hand Tool with Interchangeable Head shown above 58075 1 Air Hand Tool with Inte...

Страница 7: ...oducts in life support applications assumes all risks of such use and indemnifies Anaheim Automation against all damages LIMITED WARRANTY AllAnaheimAutomation products are warranted against defects in...

Отзывы: