AMX VPX-1701 Скачать руководство пользователя страница 35

User Manual - VPX-1701

35

No.

Function Description Syntax

Example

17

VIDOUT_RES_REF

To set output resolution

Command:

SEND_COMMAND <DEV>,”’VIDOUT_RES_

REF-<horizontal>x<vertical>,<refresh-

rate>’”
Return:

NULL
Description:

Variables:

horizontal = An integer value representing 

the horizontal.

vertical = An integer value representing the 

vertical. May have an additional qualifier 

such as ‘i’ or ‘p’.

refresh-rate = An integer value 

representing the refresh rate.

{

      4096x2160,60

      4096x2160,30

      4096x2160,25

      4096x2160,24

      3840x2160,60

      3840x2160,50

      3840x2160,30

      3840x2160,25

      3840x2160,24

      1920x1200,60

      1920x1080,60

      1920x1080,50

      1280x720,60

      1280x720,50

      1680x1050,60

      1600x1200,60

      1600x900,60

      1440x900,60

      1366x768,60

      1360x768,60

      1280x1024,60

      1280x960,60

      1280x800,60

      1280x768,60

      1024x768,60

      800x600,60             

}

Command: 

SEND_COMMAND VIDEO_OUTPUT_1,”’VIDOUT_

RES_REF-1280x1024,60’”
Return:

VIDOUT_RES_REF-1280x1024,60
Description:

Set HDMI out resolution as 1280x1024@60.

18

?VIDOUT_RES_REF 

To get output resolution

Command:

SEND_COMMAND <DEV>, “’?VIDOUT_RES_

REF’”
Return:

VIDOUT_RES_REF-

<horizontal>x<vertical>,<refresh-rate>
Description:

<horizontal>x<vertical>,<refresh-rate>

{

     4096x2160,60

     4096x2160,30

… …

    1024x768,60

    800x600,60  

}

Command:

SEND_COMMAND VIDEO_

OUTPUT_1,”’?VIDOUT_RES_REF’”
Return:

VIDOUT_RES_REF-3840x2160,60
Description:

HDMI out resolution is 3840x2160@60.

19

REBOOT

To cause a warm reboot

Command:

SEND_COMMAND <DEV>, “’REBOOT’”
Return:

REBOOT
Description:

Cause a warm reboot.

Command:

SEND_COMMAND 5002:1:0, “’REBOOT’”
Return:

SEND_COMMAND 5002:1:0, “’REBOOT’”
Description:

Cause a warm reboot.

NetLinx Command List Instructions (cont.)

Содержание VPX-1701

Страница 1: ...USER MANUAL VERSION V1 0 0 VPX 1701 7x1 2 Scaling Presentation Switcher A V FOR AN IT WORLD...

Страница 2: ...ck or fire The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanyi...

Страница 3: ...bject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation...

Страница 4: ...g 12 OSD 14 Input Source Switching 15 Auto Switching 15 Manual Switching 15 IR Operation 16 Control the Source 16 RS232 Operation 17 NetLinx Control 18 Device Number and Ports 18 Send command to contr...

Страница 5: ...1701 5 Output Resolution Setting 26 Network 26 System 27 Firmware Upgrade 28 Before Starting 28 Transferring KIT Files 28 Troubleshooting 29 API Command List Instructions 30 NetLinx Commands 30 Telnet...

Страница 6: ...T receiver The VPX 1701 simplifies integration and installation of a small presentation system for classrooms and small offices providing localized presentation switching support over long distances F...

Страница 7: ...16 9 VIC 33 1920 x 1080p 25 Hz 16 9 VIC 34 1920 x 1080p 29 97 30 Hz 16 9 VIC 39 1920 x 1080i 50 Hz 16 9 VIC 41 1280 x 720p 100 Hz 16 9 VIC 42 720 x 576p 100 Hz 4 3 VIC 43 720 x 576p 100 Hz 16 9 VIC 44...

Страница 8: ...ischarge Power Supply 100 240V AC Power Consumption Max 45W Device Dimension W x H x D With mounting brackets 482 6mm x 43 5mm x 300mm 19 x 1 71 x 11 81 Without mounting brackets 440mm x 43 5mm x 300m...

Страница 9: ...urce as the current source input The button function can be enabled through command control or WEB UI on NetLinx LED LED is located on the top of the selection button When the button function is enabl...

Страница 10: ...t device such as a PC 8 RS 232 IR Connector Connect to an RS232 enabled device and an IR device 9 LAN 10 100 Connect to an Ethernet device 10 RESET When the VPX 1701 is powered on use a pointed stylus...

Страница 11: ...The following figures show the pinouts of the Phoenix Connectors RS232 IR Connects to the RS232 and IR devices with the 6 pole 3 5mm captive screw connectors Audio IN OUT Connect to audio device with...

Страница 12: ...at 5e 6 6a 7 cable 5 Connections for additional control options LAN control NetLinx Telnet Web UI Connect a Local Area Network to the LAN port of the VPX 1701 Input source switching control Connect a...

Страница 13: ...User Manual VPX 1701 13...

Страница 14: ...display its IP address Follow these steps to initiate OSD 1 Press and Hold the front panel buttons VGA IN 1 and VGA IN 2 for at least 3 seconds 2 The IP address of the VPX 1701 will display on the upp...

Страница 15: ...l first be switched to the most recently selected port If the port has no active source the input will be switched to the active source with the highest priority Note When in Auto Switching Input Sele...

Страница 16: ...display from the source location Control the Source To control the source from the display location 1 Connect an IR emitter to IR port of the VPX 1701 2 Connect a broadband IR receiver to the IR IN p...

Страница 17: ...er or Slave Device to the RS232 port of the VPX 1701 with an RS232 cable See Pinout Information Section for RS232 wiring 2 Connect an RS232 Slave or Master Device to the RS232 port of an HDBT receiver...

Страница 18: ...its own Device Number which is assigned when the unit is bound to a Control System and the following ports Port 1 VGA IN 1 AUDIO IN 1 HDMI OUT AUDIO OUT HDBT OUT Port 2 VGA IN 2 AUDIO IN 2 Port 3 HDM...

Страница 19: ...a device Click Diagnostics on the menu bar select Control a Device A window will display as follows type the Device number Port number System and command respectively and click Send To Device For API...

Страница 20: ...ENT Window via User Defined Program The Telnet window opens 2 At the prompt type the Telnet command and press Enter If you select Launch TELENT Window via User Defined Program you may need to enable T...

Страница 21: ...al VPX 1701 21 Web UI Control via NetLinx To configure and control the device on the Web right click the Device Number in the Online Tree Tab choose Web Control Page Launch Web Control Page via NetLin...

Страница 22: ...udio s Online Tree select Web Control Page Launch Web Control Page via Default Browser or select Launch Web Control Page via NetLinx Studio The following page will pop up Enter the default password ad...

Страница 23: ...ngs To reset the device to factory default settings 1 Click Factory Default button 2 Click OK to proceed A successful reset will restore all the device settings to their factory defaults and the devic...

Страница 24: ...ick to disable Auto Switch Key Lock Key Lock allows locking of the buttons on the VPX 1701 to prevent accidental or unwanted switching ON Click to enable Key Lock OFF Click to disable Key Lock default...

Страница 25: ...lick to disable the Auto Display Control Default setting DELAY TIME 1 30 min Click the down arrow to set the time for the display to power off automatically when no signal is present Example With the...

Страница 26: ...resolution as required APPLY Click to set the output resolution to the desired setting Network Device IP Mode DHCP When enabled the IP address of the VPX 1701 will be assigned automatically by the co...

Страница 27: ...r By default it is disabled to be configured 2 LOGIN PASSWORD LOGIN PASSWORD The Login Password can be changed Default Login Password is admin 3 TELNET SSH ACCESS TELNET SSH ACCESS is used to enable o...

Страница 28: ...ected click OK Transferring KIT Files 1 In NetLinx Studio choose Tools Firmware Transfers Send to NetLinx Device to open the Send to NetLinx Studio dialog 2 Click to navigate to the target directory T...

Страница 29: ...ices Ensure picture can be shown normally when directly connecting a source to a display device 4 Cable Plug the HDMI Cat X cable in and out or connect a different HDMI Cat X cable Ensure the specific...

Страница 30: ...ommands Device Port Name and Port Number Model name Port name Port No VPX 1701 VGA IN 1 Audio in 1 1 VGA IN2 Audio in2 2 HDMI IN 3 3 HDMI IN 4 4 HDMI IN 5 5 HDMI IN 6 6 HDMI IN 7 7 HDMI OUT 1 Audio ou...

Страница 31: ...P_LOCKOUT DISABLE Return FP_LOCKOUT DISABLE Description Set Key Lock off 4 FP_LOCKOUT To verify the Key Lock Status Command SEND_COMMAND DEV FP_LOCKOUT Return FP_LOCKOUT ENABLE DISABLE Command SEND_CO...

Страница 32: ...EC_DISP_AUTO OFF Description Define the display control automatically off 10 CEC_DISP_AUTO To verify the display control Status Command SEND_COMMAND DEV CEC_DISP_ AUTO Return CEC_DISP_AUTO ON OFF Comm...

Страница 33: ...20x1200 60 1920x1080 60 1680x1050 60 1600x900 60 1440x900 60 1360x768 60 1280x768 60 1024x768 60 For HDMI Input 3840x2160 60 3840x2160 30 1920x1080 60 1280x720 60 1920x1200 60 1680x1050 60 1600x1200 6...

Страница 34: ...and SEND_COMMAND VIDEO_INPUT_1 VIDIN_ PREF_EDID Return VIDIN_PREF_EDID 1920x1200 60 Description the EDID of the Input is fix EDID 1920x1200 60Hz 2CH 15 VIDIN_HDCP To Set Input HDCP Compliant Command S...

Страница 35: ...68 60 1360x768 60 1280x1024 60 1280x960 60 1280x800 60 1280x768 60 1024x768 60 800x600 60 Command SEND_COMMAND VIDEO_OUTPUT_1 VIDOUT_ RES_REF 1280x1024 60 Return VIDOUT_RES_REF 1280x1024 60 Descriptio...

Страница 36: ...ble 24 VIDOUT_MUTE Gets the video mute mode for the video output port Command SEND_COMMAND DEV VIDOUT_ MUTE Return VIDOUT_MUTE ENABLE DISABLE Command SEND_COMMAND SWITCHER VIDOUT_ MUTE Return VIDOUT_M...

Страница 37: ...ue 0 100 Command SEND_COMMAND AUDIO_OUTPUT_1 AUDOUT_MAXVOL Return AUDOUT_MAXVOL 100 Description Audio max is 100 33 AUDOUT_MINVOL Set the audio min vol for the audio output port Command SEND_COMMAND D...

Страница 38: ...defaults reset factory 7 set date Set the current date set date Usage set date day month year Arguments day integer of day of the week between 1 and 31 month integer of month between 1 and 12 year int...

Страница 39: ...bug Enable all system debug messages info Enable info system log level warning Enable warning system log level error Enable error system log level off Disable system log output to terminal session Exa...

Страница 40: ...ode Icsp_Auto System Number 1 Master Ip URL Master Port 1319 23 set telnet username Set telnet service login username set telnet username Enter Telnet new username 123 Would you like to set this usern...

Страница 41: ...conference rooms classrooms network operation command centers homes hotels entertainment venues and broadcast facilities among others AMX is part of the HARMAN Professional Group the only total audio...

Отзывы: