UDM-RX02N Wiring and Connections
43
UDM-0808-SIG, UDM-RX02N and UDM-ABB-8-SIG Operation /Reference Guide
CONTROL Connectors
The CONTROL connectors on the UDM-RX02N include the SERIAL (RJ12) connector, the IR Rx
(IR receive), and IR Tx (IR transmit) ports.
SERIAL (RJ12) Port
The SERIAL (RJ12) port (FIG. 37) allows administrators to control the various functions to the UDM-RX02N
from a command line prompt and terminal connection.
Requires a DB9-to-RJ12 adapter cable (FG-RS01) to connect to a PC.
Default settings = 9600, 8 bit, No Parity, 1 Stop Bit.
The Serial port can also be used as a control port for sending serial data to a connected device. In this mode the
UDM-RX02N supports baud rates from 1200 - 115200. If a display device is controlled using a serial
connection instead of IR, then a serial cable is connected from the UDM-RX02N to the serial port on the
display device.
Depending on the screen manufacturer, it may be necessary to introduce a cross into this connection by instead
using the FG-RS02 cable, or a null modem DB9-DB9 adaptor with the FG-RS01. In some cases the null
modem adaptor may need a link between RTS/CTS at the DB9 end.
For example, NEC LCD panels act as DTE equipment and work with standard serial cable, while Fujitsu and
Panasonic Plasma screens act as DCE equipment and therefore require cross connections.
FIG. 38 describes the pinouts on the SERIAL (RJ12) connector.
The UDM-RX02N can be controlled via SEND_COMMANDS (UDM-0808-SIG), or via
the (optional) UDM-RC05 IR Remote Control (FG-UDM-RC05)
FIG. 37
UDM-RX02N - SERIAL Port
SERIAL (RJ12) Port
The baud rate on the UDM-RX02N must match the baud rate as the receiver is set up
for. For example, if the baud rate has been changed to 115200 for a certain display,
then you’ll need to change your terminal to the same 115200 baud rate.
Also note that you must type ‘setup’
within
30 seconds of powering up
- after this
time period, anything typed will be sent back to the UDM Hub.
FIG. 38
SERIAL Connector - RJ12 Pinouts/Descriptions
1
6
RJ12 Pinouts
Pin
1
2
3
4
5
6
NAME
DCD / DTR
DSR
TD
RD
SGND
SGND
DESCRIPTION
Data Carrier Detect / Data Terminal Ready
Data Set Ready
Transmit Data
Receive Data
Ground
Ground
RCS
RTS
RI
not used
not used
not used
Clear To Send
Request To Send
Ring Indicator
Содержание UDM-RX02N
Страница 22: ...UDM 0808 SIG Wiring and Connections 12 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 44: ...UDM 0808 SIG WebConsole 34 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 48: ...UDM 0808 SIG Firmware Upgrades 38 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 68: ...UDM RX02N NetLinx Programming 58 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 72: ...UDM RX02N Firmware Upgrades 62 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 76: ...UDM RX02N IR File Transfers 66 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 80: ...UDM RC05 Multi Format IR Remote Control 70 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...
Страница 86: ...UDM ABB 8 SIG Audio Breakout Box 76 UDM 0808 SIG UDM RX02N and UDM ABB 8 SIG Operation Reference Guide ...