Connecting Dry Closures:
Use the 8 (+ common) dry closures with a WPD8 eight-button wall panel.
Setting AXlink and PROlink Address Numbers:
Lighting Application Drawings
FIG. 5
Dry closures connection
1
2
3
4
5
6
7
8 COM
Each contact (1 - 8) is pre-
programmed with a default preset.
Refer to the
AMX Lighting Control
System
instruction manual for
details on dry closure default presets
and recording new presets.
FIG. 6
Setting AXlink and PROlink address numbers
AXlink Address
PROlink Address
Test
Set the AXlink address number
(1-255) for the RDD-DM6. This
number must match the device
number in your Axcess program.
Use the PROlink DIP switch to set
the PROlink address number for the
RDD-DM6 (1-10).
Pin 8 on the PROlink DIP switch is
a test switch that turns all circuits on
to full.
FIG. 7
Method A
FIG. 8
Method B
Method A
120 VAC 1Ø /
Single-phase, six load
Method B
120/208-240 VAC 1Ø /
Single-phase, six load