GENERAL

 overview:

• Read and understand all instructions before installation 

• Never install products during a lightning storm 

• These products are intended for indoor use only 

• Protection devices are intended for use as secondary surge protection at the 

equipment level behind a primary building protector designed for lightning effects 
protection. 

• Always keep cord lengths between equipment and protector to a minimum, try not 

to exceed 10 inches 

• Ground wires must be attached directly to metal chassis of equipment to be protected 

• Verify that metal equipment chassis are connected to earth ground via properly 

grounded AC outlet 

• Protectors reset after each surge.  In the unlikely event of a catastrophic surge, the 

protector will self sacrifice and not allow damaging surges to reach your equipment

NXA-TSJ45

 informations: 

• Confirm power off to the equipment being protected 

• Disconnect incoming data 

• Connect the small cable to the end closest to the ground wire 

• Attach the green gound wire to the metal chassis 

• Attach the incoming wire to other suppressor opening 

• Apply power 

NXA-MPS16F

 information:

• Remove power to unprotected equipment 

• Install the 19" rack mount unit to the rack 

• Verify rack grounding

• Port 1 - Ethernet; all others are NetLinx 

• Disconnect incoming data line from equipment and connect to "in" port on the rack unit 

• Connect cable to corresponding "out" port and reconnect to equipment 

• Apply power to equipment