Reserved Identifiers
151
NetLinx Programming Language Reference Guide
Keywords & Run-Time Library Functions (Cont.)
SET_SYSTEM_NUMBER
Sets the system number of the NetLinx master. The new system number will
take effect after the system has been rebooted.
SLONG SET_SYSTEM_NUMBER (INTEGER newSystemNum)
Parameters:
•
newSystemNum
: Desired new system number
Result:
• 0: Operation was successful.
• -1: System number is invalid.
• -2: Assignment of system number causes conflict.
This function only affects the master's system number, not the system number
of any attached devices. Therefore, any devices with pre-programmed system
numbers will no longer communicate with this master.
SET_SYSTEM_NUMBER (3) // set new system number
SET_TIMER
This keyword resets the system timer. The system timer counts up in 1/10th
second units. The value passed to this function (
TIME
) may be any unsigned
32-bit variable or constant. This provides a timer with a maximum range of over
13 years.
SET_TIMER (TIME)
Note
: The system timer is reset to zero on power up.
SET_VIRTUAL_CHANNEL_
COUNT
This function lets the programmer override the default number of channels that
a virtual device port maintains. By default every virtual device port maintains
the state of channels 1-255 inclusive.
SET_VIRTUAL_CHANNEL_COUNT(DEV Device, INTEGER Count)
Parameters:
•
Device
: The virtual device port to modify.
•
Count
: The number of channels that the specified virtual device port should
maintain.
SET_VIRTUAL_CHANNEL_COUNT (dvVirtual,1024) // 1024
channels
SET_VIRTUAL_LEVEL_
COUNT
This function lets the programmer override the default number of levels that a
virtual device port maintains. By default, every virtual device port maintains the
state of levels 1-8 inclusive.
SET_VIRTUAL_LEVEL_COUNT (DEV Device,INTEGER Count)
Parameters:
•
Device
: The virtual device port to modify.
•
Count
: The number of levels that the specified virtual device port should
maintain.
SET_VIRTUAL_LEVEL_COUNT (dvVirtual,10) // make it have 10
levels
SET_VIRTUAL_PORT_
COUNT
This function lets the programmer override the default number of ports that a
virtual device maintains. By default every virtual device maintains the state of a
single port (port 1).
SET_VIRTUAL_PORT_COUNT(DEV Device, INTEGER Count)
Parameters:
•
Device
: The virtual device to modify.
•
Count
: The number of ports that the specified virtual device should maintain.
SET_VIRTUAL_PORT_COUNT (dvVirtual,2) // 2 ports
SINTEGER
This keyword defines an intrinsic data type representing a 16-bit signed
integer.
SLONG
This keyword defines an intrinsic data type representing a 32-bit signed
integer.
Содержание NETLINX PROGRAMMING LANGUAGE
Страница 15: ...Table of Contents xiii NetLinx Programming Language Reference Guide...
Страница 16: ...xiv NetLinx Programming Language Reference Guide Table of Contents...
Страница 18: ...Introduction 2 NetLinx Programming Language Reference Guide...
Страница 76: ...Language Elements 60 NetLinx Programming Language Reference Guide...
Страница 106: ...Combining Devices Levels and Channels 90 NetLinx Programming Language Reference Guide...
Страница 112: ...Master To Master M2M 96 NetLinx Programming Language Reference Guide...
Страница 114: ...Mainline 98 NetLinx Programming Language Reference Guide FIG 1 Message and Mainline Processing in the NetLinx System...
Страница 182: ...Reserved Identifiers 166 NetLinx Programming Language Reference Guide...
Страница 204: ...NetLinx UniCode Functions 188 NetLinx Programming Language Reference Guide...
Страница 244: ...Appendix B Glossary 228 NetLinx Programming Language Reference Guide...
Страница 245: ...Appendix B Glossary 229 NetLinx Programming Language Reference Guide...