NXC-VAI4 Analog Voltage Control Card
29
NetLinx Cardframe, Control Cards, and NetModules
Channel Assignments
The channel ON/OFF assignments for the NXC-VAI4 are described in the following table.
Off = 50% voltage, and all channel assignments are mutually exclusive.
NXC-VAI4 Channel Assignments
Channel State
Function
1
ON
While channel 1 is ON, the voltage on Output 1 will ramp up at the "CURRENT
OUTPUT 1 RAMP UP TIME" rate. The voltage ramp stops if the maximum is reached.
OFF
Stops voltage ramping on Output 1 at current value.
2
ON
While channel 2 is ON, the voltage on Output 2 will ramp up at the "CURRENT
OUTPUT 2 RAMP UP TIME" rate. The voltage ramp stops if the maximum is reached.
OFF
Stops voltage ramping on Output 2 at current value.
3
ON
While channel 3 is ON, the voltage on Output 3 will ramp up at the "CURRENT
OUTPUT 3 RAMP UP TIME" rate. The voltage ramp stops if the maximum is reached.
OFF
Stops voltage ramping on Output 3 at current value.
4
ON
While channel 4 is ON, the voltage on Output 4 will ramp up at the "CURRENT
OUTPUT 4 RAMP UP TIME" rate. The voltage ramp stops if the maximum is reached.
OFF
Stops voltage ramping on Output 4 at current value.
5
ON
While channel 5 is ON, the voltage on Output 1 will ramp down at the "CURRENT
OUTPUT 1 RAMP DOWN TIME" rate. The voltage ramp stops if the minimum is
reached.
OFF
Stops voltage ramping on Output 1 at current value.
6
ON
While channel 6 is ON, the voltage on Output 2 will ramp down at the "CURRENT
OUTPUT 2 RAMP DOWN TIME" rate. The voltage ramp stops if the minimum is
reached.
OFF
Stops voltage ramping on Output 2 at current value.
7
ON
While channel 7 is ON, the voltage on Output 3 will ramp down at the "CURRENT
OUTPUT 3 RAMP DOWN TIME" rate. The voltage ramp stops if the minimum is
reached.
OFF
Stops voltage ramping on Output 3 at current value.
8
ON
While channel 8 is ON, the voltage on Output 4 will ramp down at the "CURRENT
OUTPUT 4 RAMP DOWN TIME" rate. The voltage ramp stops if the minimum is
reached.
OFF
Stops voltage ramping on Output 4 at current value.
9
ON
Reserved [do not use]
OFF
Reserved [do not use]
10
ON
While channel 10 is ON, the voltage on Output 1 is set to 100%
OFF
Sets Output 1 voltage to 50%.
11
ON
While channel 11 is ON, the voltage on Output 2 is set to 100%
OFF
Sets Output 2 voltage to 50%.
12
ON
While channel 12 is ON, the voltage on Output 3 is set to 100%
OFF
Sets Output 3 voltage to 50%.
13
ON
While channel 13 is ON, the voltage on Output 4 is set to 100%
OFF
Sets Output 4 voltage to 50%.
14
ON
While channel 14 is ON, the voltage on Output 1 is set to 0%
OFF
Sets Output 1 voltage to 50%.
15
ON
While channel 15 is ON, the voltage on Output 2 is set to 0%
OFF
Sets Output 2 voltage to 50%.
16
ON
While channel 16 is ON, the voltage on Output 3 is set to 0%
OFF
Sets Output 3 voltage to 50%.
Содержание NetLinx NXC-COM2
Страница 4: ......
Страница 8: ...iv NetLinx Cardframe Control Cards and NetModules Table of Contents...
Страница 14: ...NXF CardFrame and NetModules 6 NetLinx Cardframe Control Cards and NetModules...
Страница 24: ...NXC I O10 Input Output Control Card 16 NetLinx Cardframe Control Cards and NetModules...
Страница 32: ...NXC IRS4 4 Port IR S Control Card 24 NetLinx Cardframe Control Cards and NetModules...
Страница 49: ...NXC VOL4 Volume Control Card 41 Enter the Document Name Here...