Installation
5
NXB-CCG-K NetLinx® Clear Connect™ Gateway
4.
Use CAT5 Ethernet cable to connect the NXB-CCG-K to the chosen network’s Master. Please refer to the Ethernet
Pin Numbering diagram (FIG. 6) for the correct connection.
Ethernet Pin Numbering
The numbering for pins in the Ethernet port is as follows:
Returning an NXB-CCG-K to Factory Default Settings
1.
Press and hold the
Reset
button (FIG. 1) on the device for 20 seconds.
2.
The Power/Status LED will start flashing slowly for approximately10 seconds, after which it will start rapidly
flashing for approximately 20 seconds and then remain on.
3.
The device has been returned to its factory default settings.
FIG. 5
Underside of NXB-CCG-K
FIG. 6
Ethernet Pin Numbering
Ethernet Pin Numbering
Ethernet:
Pin #:
T+Ve
1
T-Ve
2
R+Ve
3
R-Ve
6
2.62"
(67.0 mm)
Returning an NXB-CCG-K to factory default settings will erase all programming from
it and all system devices and will require all Clear Connect devices to be
reprogrammed into the system
Returning the NXB-CCG-K to its factory default settings does not do the same for any
connected Lutron Clear Connect devices. They may have to be returned to factory
defaults separately before being reattached to the NXB-CCG-K’s network.