For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
1/09
©2009 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.
AMX reserves the right to alter specifications without notice at any time.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com
93-2104
REV: B
ICSNet Connections/Wiring
This connector uses a standard CAT5 Ethernet cable to provide
communication between the CardFrame and the NetLinx control system
processor. The following table shows the signal and pinout information
associated with the ICSNet connections.
Note:
ICSHub cable information is used when connecting an NXF-MINI (from
the rear ICSNet connector) to an external Hub (ex: ICSHub connector port on
an NXC-NH).
ICSHub Connections/Wiring
The following table shows the ICSHub pinout wiring, coloring, and functionality.
ICSNet Signals and Pinouts
Pin
Signal-Master
Signal-Device
1
TX +
RX +
2
TX -
RX -
3
N/A
N/A
4
GND
GND
5
N/A
N/A
6
N/A
N/A
7
RX +
TX +
8
RX -
TX -
ICSHub Pinout Information (EIA/TIA 568 B)
Pin
Wire Color
Polarity
Function
1
Orange/White
+
Transmit
2
Orange
-
Transmit
3
Green/White
-
-
4
Blue
-
-
5
White/Blue
+
-
6
Green
+
-
7
White/Brown
+
Receive
8
Brown
-
Receive
TIA 568B
1 2 3 4 5 6 7 8
1
2
3
4
5
6
7
8
RJ-45 connector - pin configurations
(female)