Introduction
13
NI-2000, NI-3000, NI-4000 Hardware Reference Guide
NI-4000 Specifications (Cont.)
Rear Panel Connectors (Cont.):
Program port
• RS-232 DB9 connector (male) can be connected to a DB9 port on a
computer; used with serial commands, NetLinx programming commands,
other DB9 capable devices, and to upload/download information from the
NetLinx Studio 2.4 program.
Configuration DIP switch
• Sets the communication parameters for the Program port.
ID pushbutton
• Provides the NetLinx ID (
Device only
) assignment for the device.
• The D notation is used to represent a device number.
• Refer to the
NetLinx Integrated Controller WebConsole & Programming
Guide
for details.
Ethernet port
• RJ-45 port for 10/100 Mbps communication. This port automatically
negotiates the connection speed (10 Mbps or 100 Mbps) and whether to
use half duplex or full duplex mode.
Ethernet Link/Activity LED
• LEDs show communication activity, connection status, speeds, and mode
information:
SPD
(speed) - Yellow LED lights On when the connection speed is 100
Mbps and turns Off when the speed is 10 Mbps.
L/A
(link/activity) - Green LED lights On when the Ethernet cables are
connected/terminated correctly, and blinks when receiving Ethernet data
packets.
AXlink LED
• Green LED indicates the state of the AXlink connector port.
• Normal AXlink activity = 1 blink/second
• Abnormal AXlink activity = cycle of 3 consecutive blinks and then Off
AXlink port
• 4-pin 3.5 mm mini-Phoenix (male) connector provides data and power to
external control devices.
Power port
• 2-pin 3.5 mm mini-Phoenix (male) connector
CardFrame Number
DIP switch
• Sets the starting address for the Control Cards in the CardFrame.(Factory
default CardFrame DIP switch value = 0).
• The Control Card address range is 1-3064.
NetLinx Control Card
connectors (1-4)
• Four 20-pin (male) connectors that bridge the gap between the Control
Cards in the CardFrame and external equipment.
Included Accessories:
• 2-pin 3.5 mm mini-Phoenix (female) PWR connector (41-5025)
• 4-pin 3.5 mm mini-Phoenix (female) AXlink connector (41-5047)
• 10-pin 3.5 mm mini-Phoenix (female) I/O connector (41-5107)
• Installation Kit (KA2105-01):
8-pin Relay Common Strip
Four rack mount screws
Four washers
• NI-4000 Quick Start Guide
• Two 8-pin 3.5 mm mini-Phoenix (female) Relay connectors (41-5083)
• Two CC-NIRC IR Emitters
• Two removable rack ears (62-2105-07)